Daewoo KOR-61155 Secondary interlock switch and interlock monitor switch, Adjustment steps, Color

Models: KOR-61155 KOR-61151

1 30
Download 30 pages 7.13 Kb
Page 21
Image 21
(2) Secondary interlock switch and interlock monitor switch

(2) Secondary interlock switch and interlock monitor switch

When the door is closed, the hook pushes the push lever downward, the push lever presses the button of the interlock monitor switch to bring it under “OFF”, condition and presses the button of the secondary interlock switch to bring it under “ON”, condition.

Interlock

Monitor

Swtich

Secondary

Interlock

Switch

Hook

Push Lever

Adjustment 2

Interlock monitor switch

When the door is closed, the interlock monitor switch should be opened before other switches close. When the door is opened, the interlock monitor switch should be closed after other switches open.

Secondary interlock switch

The movement of the switch button should exceed 1.2mm measured at the top of the button.

(3)Adjustment steps

a)Loosen the two mounting screws.

b)Adjust interlock switch assembly position.

c)Confirm the gap (1.2mm) described above.

d)Make sure that push lever moves smoothly after adjustments is completed.

e)Completely tighten the two mounting screws.

NOTE : Microwave emission test should be performed after adjusting interlock machanism. If the microwave emission exceed 4mW/cm2, readjust interlock mechanism.

(4) Interlock switch replacement

Whenever safety interlock switch are replaced:

1)Refer to the following diagram.

2)Check the connection of monitor switch after replacement.

3)Perform the electrical continuity check of interlock switches and microwave emission test mentioned in this manual.

Secondary

Interlock

Switch

WH

Interlock

Monitor RD

Switch

WH

Primary

Interlock

Switch

SYMBOL

COLOR

RD

RED

 

 

WH

WHITE

WH

BK

BL

RD

RD

RD

WH

BK

BLACK

BL

BLUE

21

Page 21
Image 21
Daewoo KOR-61155 Secondary interlock switch and interlock monitor switch, Adjustment steps, Interlock switch replacement