INTERLOCK MECHANISM AND ADJUSTME NT
The door lock mechanism is a device which has been specially designed to completely eliminate microwave radiation when
the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.
(1) Primary interlock sw itc h
When the doo r is clos e d, the h o ok lock s the ove n door. If th e door i s n o t closed prope rl y, th e oven w ill not op erate.
When the door is closed, the hook pushes the button of the microswitch. Then the button of the primary interlock switch
bring it under ON condition.
(2) Secondary interlock switch and interlock monitor switch
When the door is closed, the hook pushes the lock lever downward. The lock lever presses the button of the interlock
monitor switch to bring it under NO condition and presses the button of the secondary interlock switch to bring it under
ON c o ndition .
(3) Adjus tm e n t ste p s
a) Loosen the one mounting screw.
b) Adjust interlock switch assembly position.
c) Make sure that lock lever moves smoothly after adjustment is completed.
d) Tighten completely one mounting screw.

ADJUSTMENT

Interloc k monito r switc h
When the door is closed, the interlock monitor switch should be changed(NO condition) before other switches are closed.
When the door is opened, the interlock monitor switch should be changed(NC condition) after other switches are opened.
NOTE
Microwave emission test should be performed after adjusting interlock mechanism. If the microwave emission exceed
4mW/cm
2
, readjust interlock mechanism.