Installation Instructions - Intergrated Application
Tools You Will Need
FOR YOUR SAFETY:
While performing installations described in this section, gloves, safety glasses or goggles should be worn.
Safety Glasses |
|
| Level |
Gloves |
|
| |
|
|
| |
|
| Flashlight | |
|
|
| Carpenters |
Drill & Hole Saw set | Measuring | Square | |
Tape |
|
Preparing the Enclosure
Electrical Requirements:
The appliance must be connected to an individual properly grounded electrical outlet, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
•It is recommended that you do not install the Beverage Center into a corner (i.e. directly beside a wall). This is to allow the door(s) to have a greater then 90° open- ing swing. A limited door swing will prevent the shelves from sliding out as intended, and may lead to damaging the door gas- ket(s).
•The rough cabinet opening must be on a level floor area and at least 24” deep* by 24” wide. The opening should also have a height of at least
•The electrical outlet may be positioned from within either side of the adjacent cabinetry, or the rear of the shaded area (as shown in Fig C.).
Important: If the electrical out- let is surface mounted (not flush) within the enclosure, the depth requirment for the installation be affected.
•If the electrical outlet is located inside the adjacent cabinetry, cut a
Fig C
|
|
| |
| *if electical outlet |
|
|
| is in adjacent |
|
|
cabinetry |
| 24” | |
|
| ||
| 2”Min* | ||
Underside of |
| ||
Countertop to |
|
|
|
Floor | Electrical Access |
|
|
|
|
|
6”
24”
Cabinets
Square
and
Plumb
*The listed depth requirment for the installation is assuming that the electrical outlet is located in the adja- cent cabinetry or is flush mounted in the rear wall, not surface mounted in the enclosure.
8