| FACTORY INSTALLED CONNECTIONS |
| (DO NOT LOOSEN) |
| TERMINAL BLOCK |
CONNECT LINE 1 | CONNECT LINE 2 |
HERE | HERE |
CONNECT NEUTRAL |
|
HERE | RED WIRE |
| |
BLACK WIRE |
|
| (NEUTRAL) |
| WHITE WIRE |
GROUND STRAP |
|
4-CONDUCTOR POWER CORD INSTALLATION
Use this method for new installations and whenever
•Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will then be accessible.
•Remove the knockout ring (1 3/8”) located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.
•Assemble a
•Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal block.
•Use only ring terminals to connect the power supply.
•Remove the
•Connect the green ground wire from power supply cord to the range using the
•Use a ¼” nut driver and remove the hex washer head nuts from the terminal block.
•Connect the outer wires to the outside terminals and the center wire to the center terminal. Securely tighten nuts for proper electrical connection.
•Tighten the strain relief screws.
•
| FACTORY INSTALLED CONNECTIONS | |
| (DO NOT LOOSEN) | |
| TERMINAL BLOCK | |
CONNECT LINE 1 | CONNECT LINE 2 | |
HERE | HERE | |
CONNECT NEUTRAL | RED WIRE | |
HERE |
| |
| (NEUTRAL) | |
BLACK WIRE | WHITE WIRE | |
| ||
GROUND STRAP | GREEN | |
GROUND WIRE | ||
|