POWER SUPPLY
• Under no circumstances should this device be used to turn the unit on or off.
• The “RESET” button must always be pushed in (engaged) for correct operation.
• The power supply cord must be replaced if it fails to reset when the “TEST” button is pushed in.

IMPORTANT SAFETY INFORMATION

POWER SUPPLY

The power cord supplied with this air conditioner contains a device

CORD

that senses damage to the power cord. To test if your power cord is

working properly, you must do the following:

1) Connect the power supply cord to an

NOTE: The power cord supplied with this air

electrical outlet.

 

conditioner contains a current leakage detection

 

 

device designed to reduce the risk of fire. In the

2) The power supply cord has two buttons

event the power supply cord is damaged, it cannot

located on the head of the plug. One button is be repaired and must be replaced with a new cord

marked “TEST”, and the other is marked

from the product manufacturer.

“RESET”. Press the “TEST” button; you will hear a click as the “RESET” button pops out.

3)Press the “RESET” button; you will hear a

click as the button engages.

4)The power supply cord is now energized

and supplying electricity to the air conditioner (on some products this is also indicated by a light on the plug head).

ENERGY-SAVING

Your Danby appliance is designed to be highly efficient in energy

TIPS

savings. Follow these recommendations for greater efficiency.

 

 

1)Select a thermostat setting that suits your comfort needs and leave at that chosen setting.

2)The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times.

3)Use drapes, curtains or shades to keep direct sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow around the unit.

4)Start your air conditioner before the

outdoor air becomes hot and uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room. Use of the automatic start/stop programmable TIMER feature can be a major asset in this regard if utilized to the fullest extent.

5)When outdoor temperatures are cool enough, turn the air conditioner off and use the FAN MODE on HIGH, MED, or LOW. This circulates indoor air, providing some cooling comfort while utilizing less electricity.

INTERNAL SAFETY

FEATURE

This unit is equipped with a fail-safe switch mechanism that prevents the unit from condensing water in the event the internal reservoir becomes full or is accidentally displaced. If this situation occurs, the (RED) WATER FULL indicator light will illuminate. This condition will remain steady until the external water tank is emptied.

NOTE: No cooling will occur until the internal tank is emptied and/or re-positioned. It may take several minutes before the compressor resumes normal operation.

CORDCAUTION: During air conditioning and dehumidifier mode, if the compressor cycle is interrupted (water full condition, unplugged, power failure, etc.) and reinstated immediately thereafter (within 3-5 minutes), a compressor protection circuit is automatically activated. The compressor cannot operate during compressor protection mode (this is normal). It may take 3-5 minutes before the protection circuit self-deactivates.

DO NOT ATTEMPT TO START THE UNIT (COMPRESSOR) DURING THIS PERIOD.