INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Remove exterior and interior packagings, wipe the outside thoroughly with a soft dry cloth and the inside with a wet, lukewarm cloth. Avoid placing the unit in a narrow recess or near any heat source, direct sunlight, or moisture. Let air circulate freely around the unit. Keep the rear of the refrigerator 2 inches away from the wall.

CHOOSING THE RIGHT LOCATION

1)Select a place with a strong, level floor.

2)Allow 2 inches of space between the back of the refrigera- tor and any adjacent wall.

3)Avoid direct sunlight and heat. Direct sunlight may affect the acrylic coating. Heat sources nearby will cause higher electricity consumption.

4)Avoid very moist places. Too much moisture in the air will cause frost to form very quickly on the evaporator, and your refrigerator will have to be defrosted more frequently.

INSTALLATION

Place the appliance firmly on a solid base. Some appliances have adjustable feet on the front side; use them to level the appliance.

CONNECTION TO POWER 

SUPPLY

Connect the appliance power cord to a properly grounded

wall outlet. The required nominal voltage and frequency are indicated on the rating plate (inside the unit or on the exterior rear wall of the unit.)

BULB REPLACEMENT

Unplug the AC power cord from the wall.

Make sure the light bulb is cool before removing.

Remove the screw that holds the light bulb cover.

Squeeze the tabs at the top and bottom of the light bulb cover simultaneously.

Remove the light bulb cover.

Unscrew the bulb.

Replace with a 10 watt bulb that is the same shape and size.

Replace the light bulb cover.