INSTALLATION INSTRUCTIONS
Be sure the appliance is properly installed and grounded by a qualified technician. It is the responsibility of the technician to be certain that your range is properly installed. Situations caused by improper installation are not covered under the warranty. Any expenses incurred due to such situations will not be paid by the manufacturer of the appliance.
WARNING: To reduce the risk of tipping the appliance by abnormal usage or improper door loading, the appliance must be secured by properly installing the
If this range is removed for any reason, service or cleaning etc,. it must be replaced as outlined in the installation instructions, before placing the range back in operation.
LEVELING A FREE
STANDING RANGE
All
IMPORTANT: Be sure to keep the leg levelers. Leveling of the range is very important.
GAS CONNECTIONS
Have the dealer where you purchased your new range install or recommend a qualified installer. Installation must conform with local codes. The range should be connected to a supply line with
IMPORTANT: Do not apply pressure directly to the range manifold pipe when tightening supply connections. The manifold pipe should be held securely at the pressure regulator to prevent twisting. Hold the pressure regulator with a wrench during the tightening of the connection, or the manifold pipe may be twisted and split, causing a dangerous leak.
Note: The installation of ranges designed for manufactured (mobile) homes must conform to specific standards and local codes.Check all piping connections in the unit for leaks. Never use an open flame to check for gas leaks. It is possible for connections made at the factory to leak due to vibrations encountered in transportation. Have any suspected leaks repaired before use by a qualified service personnel.
ELECTRICAL | Your range is grounded with a | |
CONNECTIONS | ||
will ground the range when plugged into a similar grounded wall receptacle. | ||
|
|
If the backgaurd of the range has a clock or light, connect the cord from the backgaurd into the special terminal block located at the top of the main back directly under the backgaurd supply cord.The appliance must be electrically grounded when installed in accordance with local codes.
5