HOST CONFIGURATION STRINGS
A

DATA FORMAT (continued)
NOT FOR PEN EMULATION INTERFACES
DESCRIPTION STRING
Code Length Tx not transmitted EE0
transmitted in variable-digit format EE1
transmitted in fixed 4-digit format EE2
Field Adjustment disable EF0
right addition EFa0d
left addition EFa1d
right deletion EFa2d
left deletion EFa3d
Field Adjustment Character EGe
Character Replacement disable character replacement EO0
first character replacement
EO1afg
second character replacement
EO2afg
third character replacement EO3afg
Address Stamping disable reader address stamping RU0
enable reader address stamping RU1
disable reader address delimiter RV0
Address Delimiter
enable reader address delimiter and select
character
RV1h
a = ASCII character.
d = a number from the Hex/Numeric Table
e, f, g, h = HEX values representing an ASCII character
a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 59.
d = a number in the range 01-32 from the Hex/Numeric Table
e = Hex value from 00 to FE
f = Hex value of the character to be replaced from 00 to FE
g = Hex value of the new character to insert from 00 to FE
FF = replace with no new character (remove character)
h = a HEX value in the range from 00 - FE representing the ASCII character.
POWER SAVE
DESCRIPTION STRING
Scan Rate 67 scans per sec. BT0
135 scans per sec. BT1
270 scans per sec. BT2
Sleep State/USB Suspend disable BQ0
enable
BQ1
Enter Sleep Timeout (100 ms) BR00-BR99
Standby enable
BM0
disable
BM1
173