HOST CONFIGURATION STRINGS
A
CODE SELECTION (continued)
DESCRIPTION STRING
Codabar disable Codabar family AD0
Standard no start/stop character equality control
nor transmission
AD111
no start/stop character equality control
but transmission
AD112
start/stop character equality control
but no transmission
AD121
start/stop character equality control
and transmission
AD122
ABC Codabar no start/stop character equality control
but transmission
AD212
Codabar ABC forced concatenation AD232
code length AD*xxxx
start/stop character case in transmission lower case ADA0
upper case ADA1
Code 128 disable Code 128 family AI0
enable Code 128 - control without transmission of check digit AI11
enable EAN 128 - control without transmission of check digit AI21
disable
EQ0
Transmit GS before
Code enable EQ1
ISBT 128 enable ISBT 128 AI31
code length AILxxxx
Code 93 disable Code 93 family AK0
enable Code 93 - control without transmission of check digit AK1
MSI disable the family AE0
no check AE1
MOD10 no tx AE2
MOD10 with tx AE3
MOD11-MOD10 no tx AE4
MOD11-MOD10 with tx AE5
MOD10-MOD10 no tx AE6
MOD10-MOD10 with tx AE7
xxxx = ASCII numbers that define the code length where:
First 2 digits = minimum acceptable code length.
Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
EXAMPLES:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.
177