Dayton 3VG79A specifications Dayton Portable Forced Air Heater, Description, Unpacking

Models: 3VG79A

1 16
Download 16 pages 21.84 Kb
Page 1
Image 1
3VG79A

Operating Instructions & Parts Manual

3VG79A

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Dayton® Portable Forced

Air Heater

Description

Dayton Model 3VG79A is a 200,000 Btu/Hr heater. This heater uses only Kerosene or No. 1 fuel oil for combustion and electricity to run the motor. It is primarily intended for indoor and outdoor temporary heating of well-ventilated buildings under construction, alteration, or repair. It may be used in agricultural, industrial, and commercial environments.

Unpacking

1.Remove all packing items supplied with heater for shipment.

2.Remove all items from carton.

3.Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

Figure 1 - Model 3VG79A

 

 

®

ELECTRICAL SPECIFICATIONS

 

 

 

Amperage

Model

Electrical Input

(during normal run)

3VG79A

120 Volt/60 Hertz

4.5

GENERAL SPECIFICATIONS

 

Output

Hot Air Output

 

Fuel Tank Capacity

Fuel Consumption

 

Model

Rating Btu

(CFM Approx)

Fuel

(U.S. Gallons)

(U.S. Gallons/Hr.)

Motor RPM

3VG79A

200,000

600

Kerosene or No. 1 fuel oil

13.5

1.4

3450

 

 

 

 

 

 

 

 

Air Pump

Heater Weight

Heater Weight

Spark Plug Gap

 

 

Model

Pressure (psi)

(Pounds - with fuel)

(Pounds - without fuel)

(Inches)

 

 

3VG79A

6

77

66

.110

 

 

 

 

 

 

 

 

 

Form 5S4068

Printed in U.S.A.

®

03430

0899/294/VCPVP

Version B - For Reduction

G016.J

Page 1
Image 1
Dayton 3VG79A specifications Dayton Portable Forced Air Heater, Description, Unpacking, General Specifications