Dayton 3VG79B operating instructions Dayton Portable Forced Air Heater, Product Identification

Models: 3VG79B

1 16
Download 16 pages 9.88 Kb
Page 2
Image 2
3VG79B

Dayton Operating Instructions and Parts Manual

3VG79B

Dayton® Portable

Forced Air Heater

Product Identification

Hot Air

Outlet

Lower

Shell

Fuel Cap

Side Cover

Ignition Control Assembly (on inside of side cover)

Figure 2 - Model 3VG79B

Upper Shell

Fan

Guard

Fuel

Tank

Power Cord

Thermostat Knob

General Safety Information

Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater.

Safety information appears throughout these instructions. Pay close attention to them. Below are definitions for the safety information listed throughout this manual.

Under this heading, installation, operat-

ing, and maintenance procedures or practices will be found that, if not carefully followed, WILL result in IMME- DIATE serious personal injury or death.

Under this head- ing, installation, operating, and maintenance proce-

dures or practices will be found that, if not carefully followed, COULD result in severe personal injury or death.

Under this heading, installation, operat-

ing, and maintenance procedures or practices will be found that, if not carefully followed, MAY result in minor personal injury, product or property damage.

IMPORTANT: Every possible circumstance that might involve a hazard cannot be anticipated. The warnings in this manual and on tags or decals affixed to the unit are therefore not all-inclusive. If a procedure, work method, or operating technique not specifically recommended by Dayton is used, you must make sure it is safe for you and others. You should also ensure that equipment will not be damaged or made unsafe by the operat- ing or maintenance method you choose.

2

Page 2
Image 2
Dayton 3VG79B operating instructions Dayton Portable Forced Air Heater, Product Identification, General Safety Information