Defy Appliances 061 800 owner manual Electrical Installation, Earth leakage

Models: 061 800

1 10
Download 10 pages 19.84 Kb
Page 3
Image 3
INSTALLATION

INSTALLATION

Aperture

1085 H x 700 W x 580 D

+3

700 _0 Aperture

32

32

1085 +3 _0

Aperture

600 +3 _0

Above floor level

Floor

60

+3

_

0

 

 

Typical section showing

ventilation requirements

Support the oven in front of the aperture and make the electrical connection before installing. This will ensure enough cable length for subsequent servicing.

Unscrew and remove the top and bottom trims to expose the fixing holes.

Secure the oven to the cabinet using suitable screws. ( Fasteners are not provided.)

Replace the top and bottom trims.

ELECTRICAL INSTALLATION

This appliance must be earthed and the manufacturer and the seller do not accept responsibility for any damage due to incorrect installation or electrical connection.”

Earth leakage

This appliance should not be connected through an earth leakage system. Refer to S.A.B.S. 0147.

Connection to the power supply must be carried out by a licensed electrician, who will ensure that the oven is correctly connected and safely earthed. The rated current is printed on the serial number label attached to the oven bottom trim.

The appliance must be connected to the mains through a double pole isolating switch which has a minimum clearance between the contacts of 3 mm. in both poles.

A means for disconnection must be provided in the fixed wiring.