Before fitting the chimneys, connect the outlet ducting (if required) and in- sert the fitted plug into the wall socket.

Remove the protective film from the chimney ducting taking care not to dam- age the polished stainless steel surface.

Fit the upper chimney duct section (the one with slotted outlets) to the ceiling mounting bracket using the self tapping screws supplied.

CEILING MOUNTING BRACKET

TOP CHIMNEY DUCT

The lower duct fits onto the extractor hood and overlaps the upper duct.

Loosely attach the lower duct bottom flange to the hood by four self tapping screws. The four screw holes are ac- cessed from the underside of the hood.

Fit the lower duct to the lower mounting bracket and tighten the four self tapping screws on the inside of the extractor hood.

Using a 3.5mm dia drill, and using the two top holes in the lower chimney duct as a guide, drill through the upper chim- ney duct.

Secure both ducts to the centre chimney mounting bracket using the self tapping screws supplied.

Grease filter.

Remove the plastic outer protective lin- ing on the grease filter before fitting to the extractor hood.

To fit the filter, engage the two lugs at the rear of the filter into the rectangular slots of the extractor hood frame, lift the filter and press the handle catch inwards .

Engage the filter and release the catch.

To remove the filter, for cleaning pur- poses, reverse the procedure described above.

Optional Carbon pad filter.

Installations featuring an outside duct do not require a carbon pad filter.

Carbon pad filters assist in removing un- wanted cooking odours from the atmos- phere.

Should you require a carbon pad filter, a factory approved kit may be purchased from your nearest Defy Service Centre or their authorised agents.

DRILL TWO 3.5mm DIA.HOLES

 

AND INSERT TWO SELF

STEEL ROD REMOVED

TAPPING SCREWS

 

 

STEEL ROD IN PLACE

CARBON PAD FILTER

GREASE FILTER

INSERT 4 SELF TAPPING

 

SCREWS TO ATTACH

 

THE LOWER CHIMNEY DUCT

 

TO THE EXTRACTOR