Defy Appliances DBO 435 Black Electrical installation, Connection to the power supply, PAGE 4 OF

Models: DBO 435 Black

1 12
Download 12 pages 25.69 Kb
Page 4
Image 4
Electrical installation.

Electrical installation.

This appliance must be earthed and the manufacturer and the seller do not accept responsibility for any damage due to incorrect installation or electrical connection.

This appliance should not be connected through an earth leakage system. Refer to S.A.N.S.10142

Support the oven in front of the aperture and make the electrical connection before installing. This will ensure enough cable length for subsequent servicing.

Connection to the power supply

The connection must be carried out by a licensed electrician, who will ensure that the oven is correctly connected and safely earthed. The rated current is printed on the serial number label attached to the oven side trim.

The appliance must be connected to the mains through a double pole isolating switch which has a minimum clearance between the contacts of 3 mm. in both poles.

A means for disconnection must be provided in the fixed wiring.

Installation

Aperture 1085 H x 700 W x 580 D

+3

700 _0 Aperture

100 MIN32

32100 MIN

1085 +3 _0

Aperture

600 +3 _0

Above floor level

Floor

60

+3

_

0

 

 

Typical section showing

ventilation requirements

Support the oven in front of the aperture and make the electrical connection before installing. This will ensure enough cable length for subsequent servicing.

Slide the oven fully into the cabinet before securing it.

PAGE 4 OF 12

Fixing holes are located on the side trims. Secure the oven by inserting small wood screws through these holes into the cabinet side wall. (screws are not provided)

It is adequate to only secure the unit on one side. (same side as the handle)

Page 4
Image 4
Defy Appliances DBO 435 Black owner manual Electrical installation, Connection to the power supply, Installation, PAGE 4 OF