Installation
Location
These units are intended for indoor use only. Be sure the location chosen has a floor strong enough to support 1000 pounds of the cabinet and contents. Reinforce the floor as necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good air circulation inside and out.
Inside cabinet: Do not pack refrigerator so full that air cannot circulate.
Outside cabinet: Be sure that the unit has access to ample air. Avoid hot corners and locations near stoves and ovens.
Leveling
A level cabinet looks better and will perform better because:
1.The drain pan will drain properly.
2.The doors will line up with the frames properly.
3.The cabinet will not be subject to undue strain.
To meet NSF standards, this unit must be sealed to the floor.
Installation of glass shelves
1.Remove stainless steel shelf bracket assemblies by sliding key slots over shoulder bolts on inside edges of posts.
2.Plug light cords into receptacles.
3.Place 0.25” safety glass shelves on brackets.
Installation of dry section front & side glass
1.Remove (2) acorn nuts on bottom side of shelf.
2.Remove top of stainless steel shelf by lifting shelf off subtop.
3.Place 0.25” thick side glass pieces into bottom channel and lower rear of stainless steel shelf.
4.Place 0.25” thick front glass piece into bottom channel and lower front of stainless steel shelf over top edge of glass.
5.Replace acorn nuts on bottom side of shelf.
Dual View Series Service and Installation Manual
Plumbing
Moisture collecting from improper drainage can create a slippery surface on the floor
CAUTION and a hazard to employees. It is the owner’s responsibility to provide a container or outlet for drainage.
Electrical connection
Refer to the wattage data on page 2, the serial tag and your local code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must run for connection of the line cord, or permanent connection to the unit.
The power switch must be turned OFF and the unit disconnected from the power source whenever performing service or maintenance functions.
Operation Information
On
Do not load the storage area in a way that restricts the air flow. Overloading will result in a loss of temperature.
Continuous opening and closing of the doors will hamper the units ability to maintain operational temperature.
Display Case Glass Replacement
Delfield professionally packages the glass in the crate to minimize the risk of freight damage. However, during shipment glass damage can happen and breakage is not covered under warranty. If your Delfield unit arrives with broken glass in the top dry section, we recommend that you purchase replacement glass locally. The table to the right lists replacement sizes for the dry top section only.
Shelves
(Top)
34.0” x 15.84”
(Center)
34.0” x 17.24”
(Bottom)
32.50” x 15.43”
Front
24.95” x 35.0”
Sides
Two Each Required:
24.57” tall;
19.38” at bottom
15.04” at top
Please call your Delfield service or sales representative if you have any questions on glass replacement.
*** All glass shelving is .25” thick safety glass.***
Delfield® | For customer service, call (800) |
™ |
|