w w w . d e l l . c o m s u p p o r t . d e l l . c o m
Table
Line 1 | Line 2 | Causes | Corrective Actions |
Message | Message |
|
|
|
|
|
|
E0780 | PROC n PRESENCE | Microprocessor is not installed | Install a microprocessor in |
|
| in socket n. | socket n. See "Replacing a |
|
|
| Processor" in your Installation |
|
|
| and Troubleshooting Guide. |
|
|
|
|
E07F0 | PROC n IERR | Faulty or improperly installed | See "Troubleshooting the |
|
| microprocessor. | Microprocessors" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. |
|
|
|
|
E07FA | PROC n THERMTRIP | Specified microprocessor is out | See "Troubleshooting System |
|
| of acceptable temperature range | Cooling Problems" in your |
|
| and has halted operation. | Installation and Troubleshooting |
|
|
| Guide. If the problem persists, |
|
|
| ensure that the microprocessor |
|
|
| heat sinks are properly installed. |
|
|
| See "Replacing a Processor" |
|
|
| in your Installation and |
|
|
| Troubleshooting Guide. |
|
|
| NOTE: The LCD continues to |
|
|
| display this message until the |
|
|
| system’s power cord is |
|
|
| disconnected and reconnected to |
|
|
| the AC power source, or the SEL |
|
|
| is cleared using either Server |
|
|
| Assistant or the BMC Management |
|
|
| Utility. See the Dell OpenManage |
|
|
| Baseboard Management |
|
|
| Controller User’s Guide for |
|
|
| information about these utilities. |
|
|
|
|
E0876 | PS n MISSING | No power available from the | See "Troubleshooting Redundant |
| PS n STATUS | specified power supply; specified | Power Supplies" in your |
|
| power supply is improperly | Installation and Troubleshooting |
|
| installed or faulty. | Guide. |
|
|
|
|
E0876 | PS n PREDICTIVE | Power supply voltage is out of | See "Troubleshooting Redundant |
|
| acceptable range; specified power | Power Supplies" in your |
|
| supply is improperly installed or | Installation and Troubleshooting |
|
| faulty. | Guide. |
|
|
|
|
E0876 | PS n AC LOST | Power source for specified power | Check the AC power source |
| PS n AC RANGE | supply is unavailable, or out of | for the specified power supply. |
|
| acceptable range. |
|
8
Information Update