Table 1-4. LCD Status Messages (continued)
Line 1 | Line 2 | Causes | Corrective Actions |
Message | Message |
|
|
|
|
|
|
E0000 | OVRFLW CHECK LOG | LCD overflow message. | Check the SEL for details |
|
| A maximum of three error | on the events. |
|
|
| |
|
| messages can display sequentially |
|
|
| on the LCD. The fourth message |
|
|
| displays as the standard overflow |
|
|
| message. |
|
|
|
|
|
E0119 | TEMP AMBIENT | Ambient system temperature is | See "Troubleshooting System |
| TEMP BMC | out of acceptable range. | Cooling Problems" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. |
E0119 | TEMP RISER | Riser card is out of acceptable |
|
| temperature range. |
See "Troubleshooting System Cooling Problems" in your Installation and Troubleshooting Guide.
E0212 | VOLT PG n | System power supply is out of | See "Troubleshooting Redundant |
|
| acceptable voltage range; faulty | Power Supplies" in your |
|
| or improperly installed power | Installation and Troubleshooting |
|
| supply. | Guide. |
|
|
|
|
E0212 | VOLT BATT ROMB | Faulty RAID battery. | Replace the RAID battery. |
|
|
| See "Activating the Optional |
|
|
| Integrated RAID Controller" |
|
|
| in your Installation and |
|
|
| Troubleshooting Guide. |
|
|
|
|
E0212 | VOLT BATT CMOS | Faulty system battery. | Replace the system battery. |
|
|
| See "System Battery" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. |
E0212 | VOLT | RISER | 5V | Riser card voltage is out of |
| VOLT | RISER |
| acceptable range; faulty or |
|
|
|
| improperly installed power |
|
|
|
| supply; faulty system board. |
Reinstall the
E0412 | RPM FAN n | Specified cooling fan is faulty, |
| FAN REDUNDANCY | improperly installed, or missing. |
| LOST |
|
See "Troubleshooting System Cooling Problems" in your Installation and Troubleshooting Guide.
Information Update