Table 1-4. LCD Status Messages (continued)

Line 1

Line 2

Causes

Corrective Actions

Message

Message

 

 

 

 

 

 

E0000

OVRFLW CHECK LOG

LCD overflow message.

Check the SEL for details

 

 

A maximum of three error

on the events.

 

 

 

 

 

messages can display sequentially

 

 

 

on the LCD. The fourth message

 

 

 

displays as the standard overflow

 

 

 

message.

 

 

 

 

 

E0119

TEMP AMBIENT

Ambient system temperature is

See "Troubleshooting System

 

TEMP BMC

out of acceptable range.

Cooling Problems" in your

 

 

 

Installation and Troubleshooting

 

 

 

Guide.

E0119

TEMP RISER

Riser card is out of acceptable

 

 

temperature range.

See "Troubleshooting System Cooling Problems" in your Installation and Troubleshooting Guide.

E0212

VOLT PG n

System power supply is out of

See "Troubleshooting Redundant

 

 

acceptable voltage range; faulty

Power Supplies" in your

 

 

or improperly installed power

Installation and Troubleshooting

 

 

supply.

Guide.

 

 

 

 

E0212

VOLT BATT ROMB

Faulty RAID battery.

Replace the RAID battery.

 

 

 

See "Activating the Optional

 

 

 

Integrated RAID Controller"

 

 

 

in your Installation and

 

 

 

Troubleshooting Guide.

 

 

 

 

E0212

VOLT BATT CMOS

Faulty system battery.

Replace the system battery.

 

 

 

See "System Battery" in your

 

 

 

Installation and Troubleshooting

 

 

 

Guide.

E0212

VOLT

RISER

5V

Riser card voltage is out of

 

VOLT

RISER

 

acceptable range; faulty or

 

 

 

 

improperly installed power

 

 

 

 

supply; faulty system board.

Reinstall the expansion-card cage. See "Installing the Expansion- Card Cage" in your Installation and Troubleshooting Guide. If the problem persists, see "Getting Help" in your Installation and Troubleshooting Guide.

E0412

RPM FAN n

Specified cooling fan is faulty,

 

FAN REDUNDANCY

improperly installed, or missing.

 

LOST

 

See "Troubleshooting System Cooling Problems" in your Installation and Troubleshooting Guide.

Information Update

7

Page 9
Image 9
Dell 2850 manual LCD Status Messages Line Causes Corrective Actions E0000, Message E0119, Guide, Temperature range