7.Obtain the updated drive firmware from the Dell PowerVault Fibre Channel Utilities CD or from the File Library at http://support.dell.com.
8.Copy the drive firmware file onto your C drive.
9.Close all application programs that access the
NOTICE: You must disable the cache on your storage processors before you update the drive firmware.
10.Disable and deconfigure both the read cache and write cache before installing a new version of the Flare and PROM code. To deconfigure means to set all mem- ory partition sizes for array caching to 0.
The firmware can now be downloaded to the
Updating the Dell PowerVault 650F/651F/630F Drive Firmware on Windows NT or Windows 2000
To update the firmware on the
630F system running Windows NT or Windows 2000, perform the following steps:
1.Click
2.Make sure that the local host machine name is listed in the Set/Get Host and Device window and click Set.
3.In the Data Detective window, click Script and then click Get Hard Drive Info.
A window appears that lists the drive information, including the firmware revision.
NOTICE: You must disable the cache on your storage processors before you update the drive firmware. See the previous section for more details.
4.In the Data Detective window, click Download, and then click Disk Firmware Download.
5.In the Download Disk Firmware window, type the path to the drive firmware file and click Download.
6.Click OK when the download is complete.
NOTE: A firmware file is created for a specific drive model; other drive models are not updated. You do not need to remove the other drive models if your sys- tem has a mixture of
7.Enable the read cache and write cache on the storage processors in the Data Supervisor or Data Administrator window.