[no] iscsi profile-compellent.
The default is: Compellent disk arrays are not detected.
Displaying iSCSI Optimization Information
To display information on iSCSI optimization, use the following show commands.
Display the currently configured iSCSI settings.
show iscsi
Display information on active iSCSI sessions on the switch.
show iscsi sessions
Display detailed information on active iSCSI sessions on the switch . To display detailed information
on specified iSCSI session, enter the session’s iSCSI ID.
show iscsi sessions detailed [session isid]
Display all globally configured non-default iSCSI settings in the current Dell Networking OS session.
show run iscsi
Examples of the show iscsi Commands
The following example shows the show iscsi command.
Dell#show iscsi
iSCSI is enabled
iSCSI session monitoring is disabled
iSCSI COS : dot1p is 4 no-remark
Session aging time: 10
Maximum number of connections is 256
------------------------------------------------
iSCSI Targets and TCP Ports:
------------------------------------------------
TCP Port Target IP Address
3260
860
The following example shows the show iscsi session command.
VLT PEER1
Dell#show iscsi session
Session 0:
--------------------------------------------------------------------------------
---
Target: iqn.2001-05.com.equallogic:0-8a0906-0e70c2002-10a0018426a48c94-iom010
Initiator:
iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000
VLT PEER2
Session 0:
--------------------------------------------------------------------------------
----
Target: iqn.2001-05.com.equallogic:0-8a0906-0f60c2002-0360018428d48c94-iom011
iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000
The following example shows the show iscsi session detailed command.
VLT PEER1
iSCSI Optimization 483