26 About Your System
0082 Yes Secondary Master
Drive - ATAPI
Incompatible
See "Troubleshooting a Hard Drive" on
page109.
0083 Yes Secondary Slave
Drive - ATAPI
Incompatible
See "Troubleshooting a Hard Drive" on
page109.
0101 Yes Warning! This
system board does
not support the
power requirements
of the installed
processor. The
processor will be run
at a reduced
frequency, which will
impact system
performance.
Ensure that your processors match and
conform to the type described in the
processor technical specifications
outlined in your system’s Getting Started
Guide.
See "Troubleshooting Processors" on
page112.
0102 Yes Error! The CPU
Core to Bus ratio or
VID configuration
has failed! Please
enter BIOS Setup
and re-config it.
The message is displayed on the screen,
an error is logged to the SEL, and user
input is required to continue. The user
can take immediate corrective action or
choose to continue booting.
0120 Yes Thermal Failure
detected by
PROCHOT#.
Ensure that the processor heat sinks are
properly installed.
See "Troubleshooting Processors" on
page112 and "Troubleshooting System
Cooling Problems" on page106.
0121 Yes Thermal Failure
detected by
PROCHOT#.
Ensure that the processor heat sinks are
properly installed.
See "Troubleshooting Processors" on
page112 and "Troubleshooting System
Cooling Problems" on page106.
Code Log in BMC Error Message Corrective Action