About Your System 43
Memory set to
minimum
frequency.
The memory frequency may
be intentionally set lower for
power conservation.
If not an intentional setting,
check any other system
messages for possible causes.
The current memory
configuration may support
only the minimum frequency.
Ensure that your memory
configuration supports the
higher frequency.
See"General Memory
Module Installation
Guidelines" on page106.
Memory tests
terminated by
keystroke.
POST memory test was
terminated by pressing the
spacebar.
Information only.
MEMTEST lane
failure detected
on
x.
Invalid memory
configuration. Mismatched
memory modules are
installed.
Ensure that the memory
modules are installed in a
valid configuration.
See"General Memory
Module Installation
Guidelines" on page106.
No boot device
available.
Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Use a bootable USB key,
optical drive, or hard drive.
Ifthe problem persists,
see"Troubleshooting an
Optical Drive" on page156,
"Troubleshooting a USB
Device" on page146,
"Troubleshooting an Internal
USB Key" on page155, and
"Troubleshooting a Hard
Drive" on page158.
See"Using the System Setup
Program and UEFI Boot
Manager" on page53 for
information on setting the
order of boot devices.
Table 1-3. System Messages (continued)
Message Causes Corrective Actions