426 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring single link LACP
12
If singleton is configured on the port, the “Key” column displays “singleton”. Refer to “CLI display of
link aggregation information” on page423 to interpret the information on the displayed output.
Also, when ports are logically brought up or down while singleton is configured on the port, the
following Syslog messages are generated:
Logical link on interface ethernet <slot#/port#> is up.
Logical link on interface ethernet <slot#/port#> is down.
PowerConnect#show link-agg
System ID: 00e0.5200.0118
Long timeout: 120, default: 120 Short timeout: 3, default: 3
Port [Sys P] [Port P] [ Key ] [Act][Tio][Agg][Syn][Col][Dis][Def][Exp][Ope]
2/1 1 1 1 Yes S Agg Syn No No Def Exp Ina
2/2 1 1 1 Yes S Agg Syn No No Def Exp Ina
2/3 1 1 singleton Yes S Agg Syn No No Def Exp Ina
2/4 1 1 singleton Yes S Agg Syn No No Def Exp Dwn