Dell M1000E manual Activating FlexAddress, FlexAddress Plus

Models: M1000E

1 86
Download 86 pages 34.71 Kb
Page 44
Image 44
FlexAddress Plus

For example:(starting_mac)00188BFFDCFA + 0xCF = (ending_mac)00188BFFDDC9

NOTE: You must lock the SD card prior to inserting in the USB "Memory Card Reader" to prevent accidently modifying any of the contents. You must unlock the SD card before inserting into the CMC.

FlexAddress Plus

The FlexAddress Plus is a new feature added to the feature card version 2.0. FlexAddress Plus expands the number of MAC addresses to 3136 from the original FlexAddress pool of 208.

Activating FlexAddress

FlexAddress is delivered on a Secure Digital (SD) card that must be inserted into the CMC to provide the chassis-assigned WWN/MAC IDs. To activate the FlexAddress feature, perform several required updates; if you are not activating FlexAddress, these updates are not required. The updates, which are listed in the following table, include server module BIOS, I/O mezzanine BIOS or firmware, and CMC firmware. You must apply these updates before you enable FlexAddress. If these updates are not applied, the FlexAddress feature may not function as expected.

NOTE: All systems purchased after June 2008 have the correct firmware versions installed.

Component

Minimum Required Version

 

 

Ethernet mezzanine card - Broadcom

Boot code firmware 4.4.1 or later

M5708t

iSCSI boot firmware 2.7.11 or later

 

 

PXE firmware 4.4.3 or later

 

 

FC mezzanine card - QLogic QME2472

BIOS 2.04 or later

 

 

FC mezzanine card - Emulex LPe1105-

BIOS 3.03a3 and firmware 2.72A2 or

M4

later

 

 

Server Module BIOS

(PowerEdge M600) BIOS 2.02 or later

 

(PowerEdge M605) BIOS 2.03 or later

 

 

PowerEdge M600/M605 LAN on

Boot code firmware 4.4.1 or later

motherboard (LOM)

iSCSI boot firmware 2.7.11 or later

 

 

 

iDRAC

Version 1.11 or later

 

 

44

Initial System Configuration

Page 44
Image 44
Dell M1000E manual Activating FlexAddress, FlexAddress Plus