196 Managing a Switch Stack
When all four units are up and running, the show switch CLI command gives
the following output:
console#show switch
At this point, if Unit 2 is powered off or rebooted due to an unexpected
failure, show switch gives the following output:
console#show switch
When the failed unit resumes normal operation, the previous configuration
that exists for that unit is reapplied by the stack master.
To permanently remove the unit from the stack, enter into Stack Config
Mode and use the member command, as the following example shows.
console#configure
console(config)#stack
console(config-stack)#no member 2
console(config-stack)#exit
console(config)#exit
console#show switch
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- --------- ------- -------- --------- ------- --------
1 Stack Member N3048 N3048 OK 6.0.0.0
2 Stack Member N3048 N3048 OK 6.0.0.0
3 Mgmt Switch N3048 N3048 OK 6.0.0.0
4 Stack Member N3048 N3048 OK 6.0.0.0
SW Management
Status
Standby
Status
Preconfig
Model ID
Plugged-
in Model
ID
Switch
Status
Code
Version
--- --------- ------- -------- ------------------- --------
1 Stack Member N3048 N3048 OK 6.0.0.0
2 Unassigned N3048 Not Present 0.0.0.0
3 Mgmt Switch N3048 N3048 OK 6.0.0.0
4 Stack Member N3048 N3048 OK 6.0.0.0