Dell R910 manual entire system ambient operating range, the inrush

Models: R910

1 50
Download 50 pages 49.12 Kb
Page 12
Image 12
entire system ambient operating range, the inrush

Power

System heat dissipation

8407 BTU/hr maximum

(at 230 V 100% load)

(with two or four 1100 W PSUs)

 

5732 BTU/hr maximum

 

(with two or four 750 W PSUs)

AC Power Supply (per power

 

supply)

 

Wattage

1100 W (High Output PSU)

 

750 W (Energy Smart PSU)

Voltage

100–240 V, 50–60 Hz, auto-ranging

Maximum inrush current

Under typical line conditions and over the

 

entire system ambient operating range, the inrush

 

current may reach 55 A per power supply for

 

10 ms or less

Batteries

 

System battery

CR 2032 3.0 V lithium coin cell

RAID battery (Optional)

4.1 V lithium ion

 

 

Physical

 

 

 

Height

17.26 cm (6.8 in)

Width

48.24 cm (18.99 in) with rack latches

 

42.20 cm (16.62 in) without rack latches

Depth

78.8 cm (31.02 in) with power supplies and bezel

 

75.3 cm (29.65 in) without power supplies and bezel

Weight (maximum

47.60 kg (105 lb)

configuration)

 

Weight (empty)

26.31 kg (58 lb)

10

Getting Started With Your System

Page 12
Image 12
Dell R910 manual entire system ambient operating range, the inrush, 78.8 cm 31.02 in with power supplies and bezel