Dell T310 manual Methodology for Memory Protection and Clearing, Dell

Models: T310

1 73
Download 73 pages 27.4 Kb
Page 72
Image 72
Table 34. Methodology for Memory Protection and Clearing

Dell

Power Supply

PSU Microcontroller

iDRAC6 Enterprise

vFlash

How is data input to this memory?

Loading flash memory requires a vendor-provided firmware file and loader program which is executed by booting up the system from a floppy or OS-based executable (Unified Server Configurator) containing the firmware file and the loader. PSUs loaded with bad firmware will not provide PSU functional behavior and result in PSU system faults.

Preloaded media before installation, or remote out-of-band upload of user data (i.e., ISO images, files) or local server read/write capability to use like a hard disk.

Table 34. Methodology for Memory Protection and Clearing

 

How is this memory write protected?

How is the memory cleared?

Planar

 

 

System BIOS SPI

 

Not possible with any utilities or applications and

Flash

Software write protected

system is not functional if corrupted/removed.

 

 

 

LOM Configuration

Not explicitly protected but special

 

Data

 

 

applications are needed to

 

 

communicate through the LOMs to

 

 

reprogram this ROM

Not user clearable

 

 

 

iDRAC6 Controller

 

 

ROM

Protected permanently by hardware

Not clearable

iDRAC6 controller

 

 

RAM

n/a

iDRAC reset

 

 

 

 

System CPLD

Requires special system specific

Not possible with any utilities or applications and

 

 

utility

system is not functional if corrupted/removed.

 

 

 

System CPLD

Not accessible

Not clearable

 

 

 

iDRAC6 Express

Writes are proxied through a

 

Internal Flash

temporary iDRAC scratchpad RAM

 

 

and not directly made from an OS or

 

 

OS application.

Not user clearable

System RAM

OS control

Reboot or power down system

 

 

 

TPM ID EEPROM

 

 

(Plug in module only)

HW read only

Not - read only

PowerEdge T310 Technical Guide

71

Page 72
Image 72
Dell T310 manual Methodology for Memory Protection and Clearing, Dell