Dell T310 manual Environmental Specifications and Operating Requirements, Non-Operating

Models: T310

1 73
Download 73 pages 27.4 Kb
Page 29
Image 29

Dell

Table 5. Environmental Specifications and Operating Requirements

Environment

Operating Requirements

Non-Operating

Requirements

 

 

 

 

 

 

 

Temperature Ranges

10 to 35 °C

 

(For Altitude ≤900 m or 2952.75 ft)

(50 to 95 °F)

 

 

 

 

 

 

 

10 to xxx °C (where xxx is

-40 to 65 °C

 

 

calculated as show in

 

 

(-40 to 149 °F)

Temperature Ranges

Note1 )

(For Altitude > 900 m or 2952.75 ft)

50 to xxx °F (where xxx is

 

 

 

calculated as shown in

 

 

 

Note2)

 

Temperature Gradient

10 °C

20 °C

Maximum per 60 Min.

 

 

 

 

 

 

Humidity Percent Ranges

20 to 80 %*

5 to 95 %+

(*Max Wet bulb

(+Max Wet bulb

Noncondensing

temperature= 29 °C)

temperature= 38 °C)

 

 

 

 

 

 

Humidity Gradient

10 %

10 %

Maximum per 60 Min.

 

 

 

 

 

 

 

Low Limits

-50 feet

-50 feet

 

(-15.2 meters)

(-15.2 meters)

Altitude Ranges

 

 

 

 

High Limits

10,000 feet

35,000 feet

 

 

(3048 meters)

(10,668 meters)

 

 

 

 

 

 

Note1: Using following formulas to calculate the maximum operating temperature (in °C) for a given altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude is stated in feet.

35 −

Maximum Altitude(in meters) - 900

°C or 35 −

Maximum Altitude(in ft) - 2952.75

°C

 

300

 

984.25

 

Note2: Using following formulas to calculate the maximum operating temperature (in °F) for a given altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude is stated in feet.

95

(Maximum Altitude(in meters) - 900)⋅1.8

°F or 95

(Maximum Altitude(in ft) - 2952.75)⋅1.8

°F

− 

300

− 

984.25

 

 

 

PowerEdge T310 Technical Guide