Dell
Table 5. Environmental Specifications and Operating Requirements
Environment | Operating Requirements |
| ||
Requirements | ||||
|
|
| ||
|
|
|
| |
Temperature Ranges | 10 to 35 °C |
| ||
(For Altitude ≤900 m or 2952.75 ft) | (50 to 95 °F) |
| ||
|
|
|
| |
|
| 10 to xxx °C (where xxx is | ||
|
| calculated as show in | ||
|
| |||
Temperature Ranges | Note1 ) | |||
(For Altitude > 900 m or 2952.75 ft) | 50 to xxx °F (where xxx is |
| ||
|
| calculated as shown in |
| |
|
| Note2) |
| |
Temperature Gradient | 10 °C | 20 °C | ||
Maximum per 60 Min. | ||||
|
| |||
|
|
|
| |
Humidity Percent Ranges | 20 to 80 %* | 5 to 95 %+ | ||
(*Max Wet bulb | (+Max Wet bulb | |||
Noncondensing | ||||
temperature= 29 °C) | temperature= 38 °C) | |||
|
| |||
|
|
|
| |
Humidity Gradient | 10 % | 10 % | ||
Maximum per 60 Min. | ||||
|
| |||
|
|
|
| |
| Low Limits | |||
| ||||
Altitude Ranges |
| |||
|
|
| ||
High Limits | 10,000 feet | 35,000 feet | ||
| ||||
| (3048 meters) | (10,668 meters) | ||
|
| |||
|
|
|
|
Note1: Using following formulas to calculate the maximum operating temperature (in °C) for a given altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude is stated in feet.
35 − | Maximum Altitude(in meters) - 900 | °C or 35 − | Maximum Altitude(in ft) - 2952.75 | °C |
| 300 |
| 984.25 |
|
Note2: Using following formulas to calculate the maximum operating temperature (in °F) for a given altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude is stated in feet.
95 | | (Maximum Altitude(in meters) - 900)⋅1.8 | °F or 95 | | (Maximum Altitude(in ft) - 2952.75)⋅1.8 | °F | ||
− | 300 | | − | 984.25 | | |||
| | |
| | |
|
PowerEdge T310 Technical Guide | 28 |