INJECTORS TABLE
|
|
|
| LP/PROPANE | NATURAL | GAS | ||
BURNERS | NOMINAL POWER | REDUCED POWER | 11” W.C.P. | 4” W.C.P. | ||||
BTU/hr | BTU/hr |
|
|
|
| |||
Ø injector | Ø injector | |||||||
|
| |||||||
|
|
|
| [1/100 mm] | [1/100 mm] | [1/100 mm] | [1/100 mm] | |
|
|
|
|
|
|
|
| |
6000 | 1500 | 72 | 32 | 118 | adjustable | |||
|
|
|
|
|
|
| ||
Triple ring (TC) | 12000 | 5000 | 102 | 65 | 170 | adjustable | ||
|
|
|
|
|
|
|
| |
| Inner crown | 2800 for NATURAL GAS (*) | 1000 (*) | 55 | 27 | 80 | adjustable | |
| 3500 for LP/PROPANE GAS (*) | (no. 1 central) | (no. 1 central) | |||||
Dual (D) |
|
|
|
| ||||
|
|
|
|
|
|
| ||
Outer crowns | 16000 for NATURAL GAS (#) | 6500 for NATURAL GAS (#) | 72 | 60 | 130 | adjustable | ||
| ||||||||
| 15000 for LP/PROPANE GAS (#) | 4500 for LP/PROPANE GAS (#) | (no. 2 outer) | (no. 2 outer) | ||||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
Oven burner (left) | 13000 | 1500 | 109 | 34 | 180 | adjustable | ||
|
|
|
|
|
|
| ||
Oven burner (right) | 9000 | 1400 | 88 | 33 | 145 | adjustable | ||
|
|
|
|
|
|
| ||
Broil burner (left) | 8500 | - | 88 | - | 146 | - | ||
|
|
|
|
|
|
| ||
Broil burner (right) | 8000 | - | 83 | - | 140 | - | ||
|
|
|
|
|
|
|
|
(*) Power calculated only with inner crown operating
(#) Power calculated with inner and outer crowns operating
J
Fig. 2.6a
Triple ring burner
J
Fig. 2.6b
OPERATIONS TO BE PER- FORMED WHEN SUBSTI- TUTING THE INJECTORS
✓Remove the gratings and the burner covers;
✓Using a wrench substitute the nozzle injectors “J” (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used.
The burner are conceived in such a way so as not to require the regulation of the primary air.
DUAL burner
J
Injector for inner crown
J
Injectors for outer crowns
Fig. 2.6c
20