SETTING THE BURNER MINIMUM

 

When switching from one type of gas to another, the minimum flow rate must also be

F

correct: the flame should not go out even when passing suddenly from maximum to

 

minimum flame.

 

 

To regulate the flame follow the instructions below:

 

Semirapid and triple ring burners

 

Light the burner

 

 

Set the gas valve to

position

 

– Remove the knob

 

 

– With a thin screwdriver pass by the hole of microswitch and turn the screw F until

 

 

adjustment is correct (fig. 2.7).

Fig. 2.7

 

 

 

Inside crown of DUAL burner

Light the DUAL burner

Set the gas valve to position

Remove the knob

Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8).

Outside crowns of DUAL burner

Light the DUAL burner

Set the gas valve to position

Remove the knob

Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8).

For LP/PROPANE gas, tighten the adjustment screws completely.