DeLonghi EC190 200 GB manual Cleaning The Boiler Outlet, Other Cleaning Operations, Descaling

Models: EC190 200 GB

1 12
Download 12 pages 37.25 Kb
Page 10
Image 10
CLEANING THE BOILER OUTLET

EC190/200 GB 6-12-2004 12:38 Pagina 10

Replace the filter and gasket on the plastic disk as shown in fig. 25.

Make sure to insert the pin on the plastic disk into the hole in the gasket indicated by the arrow in fig. 25.

Replace the assembly in the steel filter container (fig. 26), making sure the pin is inserted into the hole in the support (see arrow in fig. 26).

Finally, screw on the cap (fig. 27).

Failure to clean as described above invalidates the resulting.

CLEANING THE BOILER OUTLET

About every 300 coffees, the espresso boiler outlet must be cleaned as follows:

Make sure the appliance is not hot and that it is unplugged from the outlet.

Using a screwdriver, unscrew the screw fixing the espresso boiler outlet filter (fig. 28).

Clean the outlet filter thoroughly in hot water using a brush. Make sure the holes are not blocked. If

necessary, clean with a pin.

Failure to clean as described above invalidates the resulting.

OTHER CLEANING OPERATIONS

1.Do not use solvents or abrasive cleaning products to clean the appliance. A soft, damp cloth is sufficient.

2.Remove the drip tray, empty and wash frequently.

3.Clean the water tank regularly.

IMPORTANT: during cleaning, never immerse the coffee machine in water. It is an electrical appliance.

DESCALING

You are recommended to descale the coffee machine about every 200 coffees.

You should use a commercially available product specifically for descaling espresso coffee machines.

If such a product is not available, proceed as follows.

1.Fill the tank with one litre of water.

2.Dissolve 2 spoonfuls (about 1 ounce) of citric acid.

3.Rotate the selector knob to the OTHER CLEANING OPERATIONS position and wait until the OK indicator light comes on.

4.Make sure the filter holder is not attached and position a container under the boiler outlet.

5.Rotate the selector knob to the DESCALING position (fig. 8) and run off half the solution in the tank.

Then interrupt the flow by rotating the selector to the "O" position (fig. 14).

6.Leave the solution to work for about 15 minutes, then run off the rest of the water in the tank.

7.To eliminate residues of solution and scale, rinse the tank well, fill with clean water and replace.

8.Rotate the selector knob to the Manual background position (fig. 8) and run off the water until the tank is completely

empty;

 

9 Rotate the selector knob to the

position (fig. 5)

and repeat operations 7 and 8 again.

Repair of damage to the coffee machine caused by scale is not covered by the resulting unless descaling is performed regularly as described above.