White Rodgers 1F87-0261 specifications Applications, Specifications, Precautions, Model

Models: 1F87-0261

1 12
Download 12 pages 40.54 Kb
Page 1
Image 1
Save these instructions for future use!

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Blue 2” Single Stage Thermostat

Installation and Operating Instructions

Model

Programming Choice

 

 

1F87-0261

7 Day Programmable

 

 

APPLICATIONS

For use with the following Class II systems:

1F87-0261 Thermostat

Single Stage systems

Single-stage heat pump systems with no Aux heat

DO NOT USE WITH:

Systems exceeding 30 VAC and 1.5 amps

3-wire zoned hydronic heating systems

SPECIFICATIONS

Electrical Rating:

 

Battery Power

mV to 30 VAC, 50/60 Hz or DC

Input-Hardwire

20 to 30 VAC

Terminal Load

1.0 A per terminal, 1.5A maximum all terminals combined

Setpoint Range

45° to 90°F (7° to 32°C)

Differential (Single Stage)

Heat 0.6°F; Cool 1.2°F (adjustable)

Differential (Heat Pump)

Heat 1.2°F; Cool 1.2°F (adjustable)

Operating Ambient

32° to +105°F (0° to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-40° to +150°F (-40° to +65°C)

Dimensions Thermostat

3-3/4”H x 4-3/4”W x 1-1/2”D

PRECAUTIONS

This thermostat is intended for use with a low voltage NEC Class II system. Do not use this thermostat with a line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

!WARNING

Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.

Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.

Thermostat installation and all components of the system shall conform to Class II (current limited) circuits per the NEC code. Failure to do so could cause a fire hazard.

 

PART NO. 37-7038B

www.white-rodgers.com

Replaces 37-7038A

0950

Page 1