TROUBLESHOOTING

Reset Operation

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, reset the thermostat

by pressing the , and TIME buttons simultaneously.

If the thermostat has power, has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Symptom

Possible Cause

Corrective Action

 

 

 

No Heat/No Cool/No Fan

1. Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2. Furnace power switch to OFF.

Turn switch to ON.

 

3. Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

panel loose or not properly installed.

interlock or door switch.

 

 

 

No Heat

1. System Switch not set to Heat.

Set System Switch to Heat and raise setpoint above

 

 

room temperature.

 

2. Loose connection to thermostat or

Verify thermostat and system wires are securely attached.

 

system

Diagnostic: Set System Switch to Heat and raise the

 

3. Heating System requires service or

setpoint above room temperature. Within a five minutes

 

thermostat requires replacement.

the thermostat should make a soft slick sound. This

 

 

sound usually indicates the thermostat is operating

 

 

properly. If the thermostat does not click, try the reset

 

 

operation listed above. If the thermostat does not click

 

 

after being reset contact your heating and cooling

 

 

service person or place of purchase for a replacement.

 

 

If the thermostat clicks, contact the furnace manufac-

 

 

turer or a service person to verify the heating system is

 

 

operating correctly.

 

 

 

No Cool

1. System Switch not set to Cool.

Set System Switch to Cool and lower setpoint below

 

 

room temperature.

 

2. Loose connection to thermostat or

Verify thermostat and system wires are securely attached.

 

system.

Same procedures as diagnostic for No Heat condi-

 

3. Cooling System requires service or

tion except set the thermostat to Cool and lower the

 

thermostat requires replacement

setpoint below the room temperature. There may be up

 

 

to a five minute delay before the thermostat clicks in

 

 

Cooling if the compressor lock-out option is selected in

 

 

the configuration menu (Item 6).

 

 

 

Heat, Cool or Fan Runs

1. Possible short in wiring.

Check each wire connection to verify they are not

Constantly

2. Possible short in thermostat.

shorted or touching together. No bare wire should

 

3. Possible short in Heat/Cool/Fan

stick out from under terminal screws. Try resetting the

 

system.

thermostat as described below. If the condition persists,

 

4. Fan Switch set to Fan On.

the manufacturer of your system or service person

 

 

can instruct you on how to test the Heat/Cool/ system

 

 

for correct operation. If the system operates correctly,

 

 

replace the thermostat.

 

 

 

Furnace CyclesToo Fast orToo Slow

1. The location of the thermostat and/

Item 4 (CR Heat) or 5 (CR Cool) in the Configuration

Cooling CyclesToo Fast orToo Slow

or the size of the Heating or Cooling

Menu is the adjustment that controls the cycle rate. If

(narrow or wide temperature swing)

System may be influencing the

an acceptable cycle rate is not achieved using the FA

 

cycle rate.

(Fast) or SL (Slow) adjustment contact a local service

 

 

person for additional suggestions.

 

 

 

Thermostat Setting and

1. Thermostat thermometer setting

The thermometer can be adjusted +/-4 degrees as

Thermometer Disagree

requires adjustment.

listed in item 8 of the Configuration Menu. No other

 

 

adjustment is possible.

 

 

 

Clock Loses or Gains Time

1. Loss of power to thermostat.

The thermostat will maintain its program in memory

 

 

even with no power but the clock time will be incorrect

 

 

when power is restored. See No Heat/No Cool /No Fan

 

 

(common problems) above for items to check in the

 

 

system.

 

 

 

Heat or Cool Starts Early

1. EMR activated.

See Configuration Menu (Item 3)

 

 

 

Thermostat Does Not Follow

1. AM or PM set incorrectly in program.

Check current clock and program settings including

Program

2. AM or PM set incorrectly on the clock.

the AM or PM designations for each time period. If a

 

3. Voltage spike or static discharge.

voltage spike or static discharge occurs use the Reset

 

4. See “Heat or Cool Starts Early” above.

Operation listed above.

 

 

 

Blank Display and/or Keypad Not

1. Voltage Spike or Static Discharge.

If a voltage spike or static discharge occurs use the

Responding

 

Reset Operation listed above.

 

 

 

9

Page 9
Image 9
White Rodgers 1F87-0261 specifications Troubleshooting, Reset Operation

1F87-0261 specifications

The White Rodgers 1F87-0261 is a sophisticated thermostat designed to improve home heating and cooling efficiency. Known for its reliability and user-friendly features, this model is widely appreciated by homeowners and HVAC professionals alike.

One of the standout features of the 1F87-0261 is its digital display, which allows users to easily read temperature settings and program schedules. The large, backlit screen ensures visibility in various lighting conditions, making it accessible for all users. This thermostat is designed for both 1-stage heating and cooling systems, and it is compatible with multisystem setups, providing flexibility for various home configurations.

The installation process of the White Rodgers 1F87-0261 is straightforward, making it an attractive option for DIY enthusiasts. The thermostat is designed to fit standard wall plates, and the clear instructions facilitate a hassle-free installation. It requires a 24V power source, commonly found in most HVAC systems.

Programming capabilities are another significant advantage of the 1F87-0261. This model offers a seven-day programmable feature, allowing users to set different schedules for each day of the week. The user can adjust temperatures for specific timeframes, ensuring optimal comfort while also saving on energy costs. The temporary hold function enables users to override programmed settings temporarily without affecting the entire schedule.

Energy-saving features are embedded within the thermostat's design. It includes a setpoint limiting option that can restrict temperature adjustments, effectively preventing overuse and contributing to reduced energy bills. Moreover, the programmable strategy encourages users to maintain more efficient temperature settings during off-peak hours when energy costs may be lower.

With an emphasis on convenience, the White Rodgers 1F87-0261 offers an intuitive interface that simplifies the programming and adjustment of temperature settings. The thermostat also boasts of a maintenance reminder feature, which alerts users when it’s time for routine HVAC system checks, thereby enhancing system longevity.

In conclusion, the White Rodgers 1F87-0261 combines user-friendly programming, energy-saving capabilities, and compatibility with a range of HVAC systems. Its practical design and innovative features make it an ideal choice for homeowners seeking efficient climate control while managing energy expenditures effectively. The reliability and performance of this thermostat have made it a trusted option in residential climate management.