V SERIES FOOD HOLDING, TRANSPORT, & BANQUET CARTS |
TROUBLESHOOTING
SYMPTOMS | POSSIBLE CAUSES | REMEDY | |
| Cabinet not connected to | Connect cabinet to power source. | |
| power source. | ||
Cabinet not operating | ON/OFF switch not ON (VHFA | Turn ON/OFF switch ON | |
series) | |||
| |||
| No power. | Check circuit breaker | |
| Check GFCI | ||
|
| ||
GFCI or Ground Fault | Moisture problem. | Dry moisture problem. | |
Shorted element | Contact Authorized Service Provider. | ||
Circuit Indicator tripped | |||
Pinched/damaged wire. | Contact Authorized Service Provider. | ||
| |||
| Damaged power cord. | Contact Authorized Service Provider. | |
Cabinet is connected to |
|
| |
power source, switch is ON, | Defective: element, |
| |
circuit breaker is ON, but | Contact Authorized Service Provider. | ||
cabinet is not heating. | thermometer, thermostat, etc. | ||
Power/Heat Indicator Light | Light faulty | Contact Authorized Service Provider. | |
not lit. | |||
| Door not shut properly or | Check door seal and Contact | |
Cabinet does not heat | needs adjustment | Authorized Service Provider. | |
Defective: element, |
| ||
properly | thermometer, thermostat, |
| |
| thermostat requires | Contact Authorized Service Provider. | |
| adjustment | ||
Fan not operating (VHFA | ON/OFF switch not ON (VHFA | Turn ON/OFF switch ON | |
series) | |||
series) | |||
Defective fan. | Contact Authorized Service Provider. | ||
|
SERVICE & PARTS INFORMATION
To obtain Service and Parts information concerning this model, contact
Customer Service 1-800-814-2028
Technical Service |
|
Service Parts |
When calling for service, have the model number and serial number available.
9