Clean the nozzle regularly with a sponge as shown in fig. 26.
15.2 Cleaning the infuser
The infuser must be cleaned regularly to avoid the
•turn the appliance off by pressing the button (fig. 6) (do not unplug) and wait for the display to go off;
•open the service door (Fig. 14);
•remove the drip tray and the grounds container (Fig. 15) and clean them;
•press the two red release buttons on the infuser sideways and towards the center (Fig. 28) and pull it out;
•IMPORTANT: THE INFUSER CAN ONLY BE REMOVED IF THE APPLIANCE IS OFF. ATTEMPTING TO REMOVE THE INFUSER WITH THE APPLIANCE ON MAY CAUSE SERIOUS DAMAGE.
•wash the infuser under running water, without using detergents. Never wash the infuser in the dishwasher;
•carefully clean the inside of the appliance. To remove the coffee stuck to the parts inside the appliance, scrape it with a plastic or wooden fork (Fig. 29) and then pick up all the residues using a vacuum clea- ner (Fig. 30);
•replace the infuser by sliding it onto the supports and pin at the bottom, then push the PUSH symbol fully in until it clicks into place.
Infuser
Push the PUSH symbol fully in until it clicks into place.
After having heard the click, check that the red buttons have snapped out.
|
| Bottom pipe on the infuser. |
Support | Pin | The pin must be inserted into the bottom |
pipe on the infuser. |
The two red buttons have snapped out CORRECTLY
The two red buttons have not snapped out
CORRECT INCORRECT
Check that the two red buttons have snapped out, otherwise the door cannot be closed.
•replace the drip tray, complete with the grounds container;
•close the service door.
NOTE 1: If the infuser is not inserted correctly, until it clicks into place, and the two red buttons have not snap- ped out, the service door cannot be closed.