Self diagnosis/Troubleshooting

Self diagnosis/Troubleshooting

SELF DIAGNOSIS

The appliance has a self diagnosis system to identify a number of malfunctions.

 

IF THE DISPLAY SHOWS …

 

 

…WHAT SHOULD YOU DO?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When

appears on the display, the ice prevention device has

 

 

 

LOW TEMPERATURE

 

been triggered.

 

 

 

 

 

 

(frost prevention)

 

 

The appliance starts up again automatically when the defrosting process is

 

 

 

 

 

 

completed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

p f

PROBE FAILURE

 

 

If this is displayed, an authorized De'Longhi service center.

 

 

 

(sensor damaged)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FULL TANK

 

 

Empty the tank on the back of the appliance and replace it correctly.

 

 

 

 

 

 

The continuous drain hose is not connected correctly or is obstructed and

 

 

 

 

 

 

the air conditioner is draining into the tank.

 

 

 

 

 

 

 

 

 

 

F I

FAILURE 1

 

 

If this is displayed, contact an authorized De'Longhi service center.

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

PROBLEM

 

 

 

CAUSE

 

 

REMEDY

 

 

 

 

 

 

 

 

 

 

 

The air conditioning

no electricity

 

 

restore electricity

 

 

unit does not start

it is not plugged into the

socket

• plug into the socket

 

 

 

 

the safety device has tripped

• reset the safety plug ( see pag. 18)

 

 

 

 

 

 

 

 

The air conditioning

the air exhaust hose or the intake hose has a

• position the exhaust hose or

 

 

unit works for a

 

constriction

 

 

 

the intake hose correctly

 

 

short time only

the air exhaust hose or the intake hose is

• check there are no obstacles

 

 

 

 

 

blocked

 

 

 

obstructing air discharge or the

 

 

 

 

 

 

 

 

 

 

intake hose

 

 

 

 

there are tight bends in the air exhaust hose

• eliminate the tight bends

 

 

 

 

 

or the intake hose

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The air conditioning

windows are open

 

close the windows

 

 

unit works, but does

there are heat sources in the room (lamp,

• eliminate the heat source

 

 

not cool the room

 

etc).

 

 

 

 

 

 

 

 

the exhaust hose is detached

• connect the exhaust hose

 

 

 

 

air filter is clogged

 

• clean or replace the filter

 

 

 

 

• Inadequate size of the room (too large)

 

 

 

 

 

 

 

 

 

 

 

Particular odor in

air filter is clogged

 

• clean or replace the filter

 

 

the room

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The air conditioning

it is normal for the compressor to start after

• wait for three minutes

 

 

unit does not ope-

 

three minutes

 

 

 

 

 

 

rate for about three

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minutes after turning

 

 

 

 

 

 

 

 

 

it on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 