OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.
Description of Operation
Become familiar with these controls before operating the unit.
On/Auto/Off Switch: Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.
Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set
Safety Valve: If the pressure switch does not shut off the air compressor at its
| Pressure |
| Switch |
Tank | On/Auto/Off |
Pressure | Switch |
Gauge | Globe Valve |
|
Safety Valve
Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.
Globe Valve: Opens and closes air discharge valve. Turn knob counter- clockwise to open and clockwise to close.
Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.
Cooling System (not shown): This compressor
contains an advanced design cooling system. At the heart of this cooling system is an engineered
fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
D26269 |