Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches
Pressure Release Valve: The pressure |
|
|
|
release valve, located on the side of the |
|
|
|
pressure switch, is designed to |
|
|
|
automatically release compressed air from |
|
|
|
| Pressure |
| |
the compressor head and the outlet tube |
|
| |
| Release |
| |
when the air compressor reaches |
| Valve |
|
pressure or is shut off. The pressure release |
|
|
|
valve allows the motor to restart freely. |
|
| Check Valve |
When the motor stops running, air will be |
|
|
|
heard escaping from this valve for a few |
|
|
|
seconds. No air should be heard leaking |
|
|
|
when the motor is running, or continuous |
|
|
|
leaking after unit reaches |
|
|
|
pressure. |
|
|
|
Air Intake Filter (not shown) This filter is |
|
|
|
|
|
|
designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See "Maintenance".
Motor Overload Protector: This motor has a manual thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart:
1.Place the On/Auto/Off lever in the Off postion.
2.Allow the motor to cool.
3.Depress the red reset button on the motor.
4.Place the On/Auto/Off lever in the On/Auto postion to restart the motor.
How to Use Your Unit
How to Stop:
1.Set the On/Auto/Off lever to "OFF".
Before Starting
Break-in Procedure
Serious damage may result if the following
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
1.Make sure the On/Auto/Off lever is in the "OFF" position.
D26269 |