TROUBLESHOOTING

TROUBLESHOOTING

For assistance with your machine, visit our website at www.deltamachinery.com for a list of service centers or call the DELTA Machinery help line at 1-800-223-7278 (In Canada call 1-800-463-3582).

MAINTENANCE

CHANGING AND CLEANING FILTERS

MAINTENANCE Disconnect unit from the power source!

1.Remove the six screws (A) Fig. 7 from the filter cover.

2.Pull the filter cover (C) Fig. 8 from the machine.

Fig. 7

CHANGING AND CLEANING FILTERS A  Disconnect unit from the power source!

Fig. 8

C

3.Remove the three spring clips (D) Fig. 9

4.Remove the bag filter (E) Fig. 9.

5.Remove the pre-filter (F) Fig. 10.

6.Depending on the condition, you can either clean or replace the filters (E) Fig. 9 and (F) Fig. 10. Clean the filters either with a shop-vac or with compressed air.

Manual background Compressed air can be dangerous. For operator safety, do not exceed 30 psi. Do not point the air nozzle toward yourself or anyone else. Always wear safety glasses and dust mask when performing this procedure.

7.Perform this operation in reverse to install the filters.

8.Replace the filters on the opposite side of the machine in the same manner.

Fig. 9

D