SHUTTING DOWN YOUR PRESSURE WASHER

SHUTTING DOWN YOUR PRESSURE WASHER

1.Place the ON-OFF switch in the OFF position.

2.Turn off water supply.

3.Pull trigger on spray gun to relieve any water pressure in hose or spray gun.

4.Disconnect water supply hose from water inlet.

5.Disconnect high pressure hose from outlet.

MAINTENANCE

When performing maintenance, you may be exposed to hot surfaces, water pressure, or moving parts that can cause

serious injury or death!

Before performing any maintenance or repair, unplug unit from power source, let motor cool and release all water pressure.

To ensure efficient operation and longer life of your pressure washer, a routine maintenance schedule should be prepared and followed. If the pressure washer is used in unusual conditions, such as high-temperatures or dusty conditions, more frequent maintenance checks will be required.

1.Check and clean the suction filter after every 50 hours of use.

3.Clean the nozzle at end of wand with the tool provided. Detach the wand from the gun and remove any dirt from the nozzle and rinse.

Figure 9

2. Check and clean the detergent

filter after every 50 hours of use.

Figure 11

 

Turn nozzle and pull to remove

 

from chemical application unit.

 

Clean filter inside nozzle by

 

flushing it with water on both

 

sides.

 

Figure 10