STORAGE

ENGINE

Consult the Engine Owners Manual for the manufacturer's recommendations for storage.

PUMP

1.Drain all water from high pressure hose, coil it, and store it in cradle of the pressure washer handle.

2.Drain all water from spray gun and spray wand by holding spray gun in a vertical position with nozzle end pointing down and squeezing trigger. Store in gun/hose holder.

3.Store chemical hose, high pressure hose, spray gun, and spray wand so they are protected from damage, such as being run over.

It is recommended that you follow these steps to protect the internal seals of the pressure washer when STORING THE UNIT FOR MORE THAN 30 DAYS AND/OR WHEN FREEZING TEMPERATURES ARE EXPECTED.

*RV antifreeze needs to be run through the pump as outlined in the steps below.

4.Obtain a funnel, six ounces of *RV antifreeze, and approximately 36 inches of garden hose with a male hose connector attached to one end.

Use only RV antifreeze. Any other antifreeze is corrosive and can damage pump.

5.Disconnect spark plug wire.

6.Connect 36 inch length of hose to water inlet of pump.

7.Add *RV antifreeze to hose as shown.

8.Pull engine starter rope slowly several times until antifreeze comes out of high pressure hose connection of pump.

9.Remove short hose from water inlet of pump.

10.Reconnect spark plug wire.

*Windshield washer fluid may also be used