INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION SYSTEM
MODELS: VFB25AX / VFB25AD / VFB25AC
VFB25AEH / VFB25ADH / VFB25ACH
READ AND SAVE THESE INSTRUCTIONS
General Safety Information |
|
|
|
|
| ||
1. | Do not install this ventilating fan where air temperature may | 8. | These models are UL listed for tub and shower enclosures. | ||||
| exceed 40°C (104°F). | 9. | Do not use this unit with any other | ||||
|
| ||||||
2. | Make sure that the electric service supply voltage is AC 110~220V, |
| |||||
| 50~60Hz. |
| cause motor humming noise. |
|
| ||
3. | Follow all local electrical and safety codes, as well as the Nation | 10. | panel and lock the service disconnecting means to prevent | ||||
| Electrical Code (NEC) and the Occupation Safety and Healthy |
| |||||
| Act (OSHA). |
| power from being switched on accidentally. When the service | ||||
4. | Always disconnect the power source before working on or near |
| disconnecting means cannot be locked, securely fasten a | ||||
| prominent warning device, such as a tag, to the service panel. | ||||||
| the ventilating fan, motor or junction box. |
| |||||
| 11. | NEVER place a switch where it can be reached from a tub | |||||
5. | Protect the power cord from sharp edges, oil, grease, hot surfaces, | ||||||
| or shower. |
|
| ||||
| chemicals or other objects. |
|
|
| |||
| 12. | Not to be installed in a ceiling thermally insulated to a value | |||||
6. | Do not kink the power cord. | ||||||
| greater than R40 (This is required for installation in Canada only). | ||||||
7. |
|
| |||||
in Fig. A. |
|
|
|
|
| ||
|
|
| Turning angle too large | Duct shrink | |||
|
|
|
|
8.Provide suction parts with proper ventilation.
9.This unit is UL listed for use over a bathtub or shower when
| installed in a GFCI protected branch circuit. |
|
|
|
10. | These ventilating fans are intended for residential usage only. |
|
|
|
WARNING | Too many elbows | Elbow near the body | ||
|
|
| ||
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR |
| Body |
| |
INJURY TO PERSONS, OBSERVE THE FOLLOWING: |
|
|
| |
1. | Use this unit only in the manner intended by the manufacturer. |
|
|
|
| If you have any questions, contact the manufacturer. |
| Fig. A |
|
2. | Before servicing or cleaning unit, switch power o at service |
|
| |
|
|
| ||
| panel and lock the service disconnecting means to prevent | CAUTION |
|
|
| power from being switched on accidentally. When the service | 1. For general ventilating use only. Do not use to exhaust hazardous | ||
| disconnecting means cannot be locked, securely fasten a | |||
| or explosive materials and vapors. |
| ||
| prominent warning device, such as a tag, to the service panel. |
| ||
| 2. Not for use in cooking area (Fig. B). |
| ||
3. |
|
| ||
person(s) in accordance with all applicable codes and standards, | 3. This product must be properly grounded. |
| ||
|
| |||
4. |
|
| Cooling Area |
|
| to prevent back drafting. Follow the heating equipment |
|
|
|
| manufacturer’s guideline and safety standards such as those |
|
|
|
| published by the National Fire Protection Association (NFPA), |
|
|
|
| and the American Society for Heating Refrigeration and Air |
|
|
|
| Conditioning Engineers (ASHRAE) and local code authorities. |
|
|
|
5. | When cutting or drilling into wall or ceiling, do not damage |
|
|
|
| electrical wiring and other hidden utilities. |
| Co ol i n g |
|
|
|
|
| |
6. | Ducted ventilating fan must always be vented to the outdoors. |
| Eq uip m en t | Fl o o r |
|
| |||
7. | If this unit is to be installed over a tub or shower, it must be |
|
|
|
| marked as appropriate for the application and be connected |
| Fig. B |
|
| to a GFCI (Ground Fault Circuit Interrupter) – protected branch |
| Fig. B |
|
|
|
|
| |
| circuit. |
|
| 1 |
|
|
|
|