Delta Slots Spring, Humidity Models VFB25AEH, VFB25ADH, VFB25ACH, Dual Speed Model VFB25AX

Models: VFB25AEH VFB25ADH VFB25AD VFB25AC VFB25ACH VFB25AX

1 7
Download 7 pages 60.25 Kb
Page 4
Image 4
7.Connect Wiring

7.Connect Wiring

7-1. Follow all local electrical and safety codes.

7-2. NEVER place a switch where it can be reached from a tub or shower.

7-3. Connect wires as shown in wiring diagrams.

7-4. Using wire nuts, connect house power wires to ventilating fan wires.

7-5. 14 AWG (2.1 mm2) is the smallest conductor that shall be used for branch-circuit wiring.

 

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

 

 

Box (Purchase separately)

Ventilation

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Live

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

Ground

 

8.Test Run and Grille Attachment

8-1. With the power on, check for abnormal vibration or sound.

8-2. Insert the mounting springs into the slots and mount the grille to the body.

Slots

Spring

9. Operation

Humidity Models: VFB25AEH, VFB25ADH, VFB25ACH

9-1. Humidity control mode: Turn on the power switch to operate humidity control mode, and LED is ON in blue.

9-2. Full speed mode: Cycling ON/OFF switch to operate full speed mode, and LED is amber.

Single Speed Models: VFB25AD, VFB25AC

9-3. Single speed control mode: Turn on the power switch to operate ON or OFF.

Dual Speed Model: VFB25AX

9-1. Low speed control mode: Turn on the power switch to operate low speed mode, and LED is green.

9-2. High speed control mode: Cycling ON/OFF switch to operate high speed mode, and LED is amber.

MAINTENANCE WARNING

Disconnect power source before working on unit. Routine maintenance must be done every year.

CAUTION

1.Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan.

2.Do not allow water to enter motor.

3.Do not soak resin parts in water over 60°C.

CLEANING

1.Pull down the spring to remove grille.

2.Wash and clean grille (Use non-abrasive kitchen detergent, wipe dry with new cloth).

3.Remove dust and dirt from ventilating fan using a vacuum cleaner.

4.Using a cloth dampened with kitchen detergent, remove any dirt from ventilating fan. Wipe dry with new cloth.

5.Replace grille.

DIMENSIONS

SPECIFICATIONS

Model No.

Voltage

Frequency

Power

Air Flow @

Weight

Note

(V)

(Hz)

(W)

0.1SP (CFM)

(lb.)

 

 

 

 

 

 

 

 

 

VFB25AEH

110-220

50-60

24.0

130

7.52

Humidity

Sensor*

 

 

 

 

 

 

 

 

 

 

 

 

 

VFB25ADH

110-220

50-60

16.4

110

7.52

Humidity

Sensor*

 

 

 

 

 

 

 

 

 

 

 

 

 

VFB25ACH

110-220

50-60

8.0

80

7.52

Humidity

Sensor*

 

 

 

 

 

 

 

 

 

 

 

 

 

VFB25AD

110-220

50-60

16.4

110

7.52

 

 

 

 

 

 

 

 

VFB25AC

110-220

50-60

8.0

80

7.52

 

 

 

 

 

 

 

 

VFB25AX

110-220

50-60

24.0

110

7.52

Dual Speed

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

*If the fan is installed in an environment with relative humidity constantly more than 40%, the fan may keep running when operating in humidity sensing mode since the relative humidity level is constantly more than 40%.

4

Page 4
Image 4
Delta manual Slots Spring, Humidity Models VFB25AEH, VFB25ADH, VFB25ACH, Single Speed Models VFB25AD, VFB25AC, Cleaning