Delta Electronics LCP-10G3B4QDR manual State/ Control Bits, Optional Set of Alarm and Warning

Models: LCP-10G3B4QDR

1 14
Download 14 pages 33.68 Kb
Page 13
Image 13

LCP-10G3B4QDR

6)

State/ Control Bits

Byte

 

Bit

Name

Description

110

7

Tx Disable State

Digital state of the Tx disable input pin

110

 

6

Soft Tx Disable

Read/ Write bit that allow software disable of laser

110

5

Reserved

 

110

 

4

Rate Select State

Rate Select State

110

3

Soft Rate Select

Software Rate Select State

110

 

2

Tx Fault

Digital state of the Tx fault output pin

110

1

LOS

Digital state of the LOS output pin.

110

 

0

Data_Ready_Bar

NA

7)

Optional Set of Alarm and Warning

Byte

 

Bit

Name

Description

112

7

Temp High Alarm

Set when internal temperature exceeds high alarm level

112

6

Temp Low Alarm

Set when internal temperature is below low alarm level

112

 

5

Vcc High Alarm

Set when internal supply voltage exceeds high alarm level

112

 

4

Vcc Low Alarm

Set when internal supply voltage is below low alarm level

112

3

Tx Bias High Alarm

Set when Tx Bias current exceeds high alarm level

112

2

Tx Bias Low Alarm

Set when Tx Bias current is below low alarm level

112

 

1

Tx Power High Alarm

Set when Tx output power exceeds high alarm level

112

 

0

Tx Power Low Alarm

Set when Tx output power is below low alarm level

113

7

Rx Power High Alarm

Set when received power exceeds high alarm level

113

6

Rx Power Low Alarm

Set when received power is below low alarm level

113

 

5-0

Reserved

 

116

7

Temp High Warning

Set when internal temperature exceeds high warning level

116

6

Temp Low Warning

Set when internal temperature is below low warning level

116

 

5

Vcc High Warning

Set when internal supply voltage exceeds high warning level

116

 

4

Vcc Low Warning

Set when internal supply voltage is below low warning level

116

3

Tx Bias High Warning

Set when Tx Bias current exceeds high warning level

116

2

Tx Bias Low Warning

Set when Tx Bias current is below low warning level

116

 

1

Tx Power High Warning

Set when Tx output power exceeds high warning level

116

 

0

Tx Power Low Warning

Set when Tx output power is below low warning level

117

7

Rx Power High Warning

Set when received power exceeds high warning level

117

6

Rx Power Low Warning

Set when received power is below low warning level

117

 

5-0

Reserved

 

Digital Diagnostic Monitor Accuracy

 

Parameter

Typical Value

 

Note

 

 

 

 

 

 

 

 

Transceiver Temperature

± 3

1

 

 

Power Supply Voltage

± 3%

 

2

 

 

TX Bias Current

± 10%

 

 

 

 

TX Optical Power

± 1.5dB

 

 

 

 

RX Optical Power

± 3dB

 

 

 

Notes:

 

 

 

 

1) Temperature is measured internal to the transceiver

 

 

 

2) Voltage is measured internal to the transceiver

 

 

 

 

 

 

13

 

Revision: 0B

 

 

 

2008/9/5

DELTA ELECTRONICS, INC.

 

 

www.deltaww.com

Page 13
Image 13
Delta Electronics LCP-10G3B4QDR manual State/ Control Bits, Optional Set of Alarm and Warning

LCP-10G3B4QDR specifications

Delta Electronics has established itself as a leader in providing innovative power solutions, and one of their notable products is the LCP-10G3B4QDR, a high-performance rack-mounted Power Distribution Unit (PDU) that addresses the growing demands of data centers and IT infrastructure.

The LCP-10G3B4QDR is designed to offer efficient power management and distribution capabilities in a compact form factor. One of its standout features is the ability to support a wide range of input voltages, allowing it to be adaptable to various electrical environments and enhancing its compatibility with existing systems.

This PDU comes equipped with 10 outlets, ensuring ample power supply to critical equipment while also minimizing the footprint required for installation. The outlets are strategically placed to ensure easy access and efficient cable management, which is essential in densely packed data center environments.

A major characteristic of the LCP-10G3B4QDR is its integrated monitoring capabilities. The unit features real-time monitoring of power consumption and environmental conditions, including temperature and humidity. This functionality is crucial for data center managers, as it enables proactive management of power use and cooling requirements, leading to improved operational efficiencies and reduced energy costs.

The device supports advanced communication protocols, including SNMP, HTTP, and HTTPS, allowing seamless integration with existing network management systems. This connectivity is important for remote monitoring and management, enabling administrators to keep track of their power distribution from virtually anywhere.

Furthermore, Delta has incorporated cutting-edge safety features into the LCP-10G3B4QDR. The device complies with international safety standards, ensuring it meets rigorous testing requirements for reliable operation. Additionally, built-in surge protection safeguards sensitive equipment from power spikes, thereby enhancing overall reliability.

In terms of design, the LCP-10G3B4QDR features a space-saving, rack-mountable format that simplifies installation in standard 19-inch server racks. Its durable construction and cooling designs ensure that it can withstand the demanding conditions of a data center environment.

In conclusion, the Delta Electronics LCP-10G3B4QDR stands out with its robust feature set, focusing on flexibility, efficiency, and safety. As data centers continue to evolve, products like the LCP-10G3B4QDR become essential for ensuring that critical operations run smoothly and efficiently.