11 Configure the alarm settings [Alarm]

Close: The alarm output terminal will close when outputting the alarm signals. (Normally open)

Default: Close

Note

When “Open” is selected, the alarm signal will be output for about 20 seconds when the power of the unit is turned on.

[Pulse width]

When “Pulse” is selected for “Alarm output”, select an alarm output terminal duration from the following.

Available range: 1-120s

Default: 1s

11.5Change the AUX name [Alarm] (BL-VT164W/ BL-VT164)

Click the [Alarm] tab on the “Alarm” page. (page 34, page 35)

The names of “AUX”, “Open” and “Close” on the “Live” page can be changed.

AUX title

[AUX (Up to 10 characters)]

Enter the name for “AUX” on the “Live” page.

Unavailable characters: " &

Default: AUX

[Open (Up to 5 characters)]

Enter the name for “Open” of “AUX” on the “Live” page.

Unavailable characters: " &

Default: Open

[Close (Up to 5 characters)]

Enter the name for “Close” of “AUX” on the “Live” page.

Unavailable characters: " &

Default: Close

Note

AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page. For example, an operator can remotely control lights in a place where the camera is installed by connecting the terminal to the light controller.