Delta Electronics OPEP-33-A4Q1RI manual Digital Diagnostic Monitoring Interface 2-Wire Address A2h

Models: OPEP-33-A4Q1RI

1 14
Download 14 pages 27.28 Kb
Page 11
Image 11

OPEP-33-A4Q1RI

Digital Diagnostic Monitoring Interface (2-Wire Address A2h)

Alarm and Warning Thresholds (2 Wire Address A2h)

Address

 

# Bytes

 

Name of Field

 

HEX

Real Value

 

Unit

00-01

 

2

 

Temp High Alarm

64 00

100

 

ºC

02-03

 

2

 

Temp Low Alarm

 

DD 00

-35

 

ºC

04-05

 

2

 

Temp High Warning

 

5A 00

90

 

ºC

06-07

 

2

 

Temp Low Warning

 

E7 00

-25

 

ºC

08-09

 

2

 

Voltage High Alarm

94 70

3.8

 

V

10-11

 

2

 

Voltage Low Alarm

 

6D 60

2.8

 

V

12-13

 

2

 

Voltage High Warning

 

87 8C

3.47

 

V

14-15

 

2

 

Voltage Low Warning

 

7A 44

3.13

 

V

16-17

 

2

 

Bias High Alarm

 

4E 20

40

 

mA

18-19

 

2

 

Bias Low Alarm

 

01 F4

1

 

mA

20-21

 

2

 

Bias High Warning

 

3A 98

30

 

mA

22-23

 

2

 

Bias Low Warning

 

01 F4

1

 

mA

24-25

 

2

 

TX Power High Alarm

 

 

 

 

 

26-27

 

2

 

TX Power Low Alarm

 

No implemented for Burst Mode.

 

28-29

 

2

 

TX Power High Warning

 

 

 

 

 

 

 

 

 

30-31

 

2

 

TX Power Low Warning

 

 

 

 

 

32-33

 

2

 

RX Power High Alarm

27 10

0

 

dBm

34-35

 

2

 

RX Power Low Alarm

 

00 0D

-29

 

dBm

36-37

 

2

 

RX Power High Warning

13 94

-3

 

dBm

38-39

 

2

 

RX Power Low Warning

00 19

-26

 

dBm

40-55

 

16

 

Reserved

 

 

 

 

 

Calibration Constants (2 Wire Address A2h)

Address

# Bytes

Name of Field

HEX

Description

56-59

4

Rx_PWR (4)

00 00 00 00

Set to zero for “internally calibrated” devices.

60-63

4

Rx_PWR (3)

00 00 00 00

Set to zero for “internally calibrated” devices.

64-67

4

Rx_PWR (2)

00 00 00 00

Set to zero for “internally calibrated” devices.

68-71

4

Rx_PWR (1)

3F 80 00 00

Set to 1 for “internally calibrated” devices.

72-75

4

Rx_PWR (0)

00 00 00 00

Set to zero for “internally calibrated” devices.

76-77

2

Tx_I (Slope)

01 00

Set to 1 for “internally calibrated” devices.

78-79

2

Tx_I (Offset)

00 00

Set to zero for “internally calibrated” devices.

80-81

2

Tx_PWR (Slope)

01 00

Set to 1 for “internally calibrated” devices.

82-83

2

Tx_PWR (Offset)

00 00

Set to zero for “internally calibrated” devices.

84-85

2

T (Slope)

01 00

Set to 1 for “internally calibrated” devices.

86-87

2

T (Offset)

00 00

Set to zero for “internally calibrated” devices.

88-89

2

V (Slope)

01 00

Set to 1 for “internally calibrated” devices.

90-91

2

V (Offset)

00 00

Set to zero for “internally calibrated” devices.

92-94

3

Reserved

00 00 00

Reserved

95

1

Checksum

XX

Checksum of bytes 0 – 94.

11

Revision: S3

 

12/20/2007

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 11
Image 11
Delta Electronics OPEP-33-A4Q1RI Digital Diagnostic Monitoring Interface 2-Wire Address A2h, Address # Bytes Name of Field