Digital Diagnostic Monitoring Interface (2-Wire Address A2h)
Alarm and Warning Thresholds (2 Wire Address A2h)
Address |
| # Bytes |
| Name of Field |
| HEX | Real Value |
| Unit |
| 2 |
| Temp High Alarm | 64 00 | 100℃ |
| ºC | ||
| 2 |
| Temp Low Alarm |
| DD 00 |
| ºC | ||
| 2 |
| Temp High Warning |
| 5A 00 | 90℃ |
| ºC | |
| 2 |
| Temp Low Warning |
| E7 00 |
| ºC | ||
| 2 |
| Voltage High Alarm | 94 70 | 3.8 |
| V | ||
| 2 |
| Voltage Low Alarm |
| 6D 60 | 2.8 |
| V | |
| 2 |
| Voltage High Warning |
| 87 8C | 3.47 |
| V | |
| 2 |
| Voltage Low Warning |
| 7A 44 | 3.13 |
| V | |
| 2 |
| Bias High Alarm |
| 4E 20 | 40 |
| mA | |
| 2 |
| Bias Low Alarm |
| 01 F4 | 1 |
| mA | |
| 2 |
| Bias High Warning |
| 3A 98 | 30 |
| mA | |
| 2 |
| Bias Low Warning |
| 01 F4 | 1 |
| mA | |
| 2 |
| TX Power High Alarm |
|
|
|
|
| |
| 2 |
| TX Power Low Alarm |
| No implemented for Burst Mode. |
| |||
| 2 |
| TX Power High Warning |
|
| ||||
|
|
|
|
|
|
| |||
| 2 |
| TX Power Low Warning |
|
|
|
|
| |
| 2 |
| RX Power High Alarm | 27 10 | 0 |
| dBm | ||
| 2 |
| RX Power Low Alarm |
| 00 0D |
| dBm | ||
| 2 |
| RX Power High Warning | 13 94 |
| dBm | |||
| 2 |
| RX Power Low Warning | 00 19 |
| dBm | |||
| 16 |
| Reserved |
|
|
|
|
|
Calibration Constants (2 Wire Address A2h)
Address | # Bytes | Name of Field | HEX | Description |
4 | Rx_PWR (4) | 00 00 00 00 | Set to zero for “internally calibrated” devices. | |
4 | Rx_PWR (3) | 00 00 00 00 | Set to zero for “internally calibrated” devices. | |
4 | Rx_PWR (2) | 00 00 00 00 | Set to zero for “internally calibrated” devices. | |
4 | Rx_PWR (1) | 3F 80 00 00 | Set to 1 for “internally calibrated” devices. | |
4 | Rx_PWR (0) | 00 00 00 00 | Set to zero for “internally calibrated” devices. | |
2 | Tx_I (Slope) | 01 00 | Set to 1 for “internally calibrated” devices. | |
2 | Tx_I (Offset) | 00 00 | Set to zero for “internally calibrated” devices. | |
2 | Tx_PWR (Slope) | 01 00 | Set to 1 for “internally calibrated” devices. | |
2 | Tx_PWR (Offset) | 00 00 | Set to zero for “internally calibrated” devices. | |
2 | T (Slope) | 01 00 | Set to 1 for “internally calibrated” devices. | |
2 | T (Offset) | 00 00 | Set to zero for “internally calibrated” devices. | |
2 | V (Slope) | 01 00 | Set to 1 for “internally calibrated” devices. | |
2 | V (Offset) | 00 00 | Set to zero for “internally calibrated” devices. | |
3 | Reserved | 00 00 00 | Reserved | |
95 | 1 | Checksum | XX | Checksum of bytes 0 – 94. |
11 | Revision: S3 |
| 12/20/2007 |
DELTA ELECTRONICS, INC. | www.deltaww.com |