PG-02 Terminal Descriptions

3

PG-02 Terminal Descriptions

Terminals

Terminal Symbols

Descriptions

 

 

 

 

 

 

 

VP

Power source of PG-02 (FSW1 can be switched to 12V or 5V)

 

Output Voltage: (+12VDC ±5% 200mA) or (+5VDC ±2% 400mA)

 

 

 

 

 

 

 

 

 

 

 

 

DCM

Power source (VP) and input signal (A, B) common

 

 

 

 

 

 

 

 

 

 

 

Input signal from Pulse Generator. Input type is selected by FSW2.

 

 

 

 

 

 

 

 

 

 

Maximum 500KP/Sec

 

 

 

 

 

 

A/O, B/O

PG-02 output signal for use with RPM Meter.

Maximum DC24V 300mA

 

 

 

 

 

 

 

 

 

COM

PG-02 output signal (A/O, B/O) common.

 

 

 

 

 

 

Wiring Notes

The control, power supply and motor leads must be laid separately. They must not be fed through the same cable conduit / trunking.

1.Please use a shield cable to prevent interference. Do not run control wire parallel to any high voltage AC power line (220 V and up).

2.Connect shielded wire to Terminals E only.

3.Recommended wire size 0.21 to 0.81mm2 (AWG24 to AWG18).

4.Wire length:

Types of Pulse

Maximum Wire Length

Wire Gauge

Generators

 

 

Output Voltage

50m

 

 

 

 

Open Collector

50m

1.25mm2 (AWG16) or above

 

 

Line Driver

300m

 

 

 

 

Complementary

70m

 

 

 

 