Delta Electronics Series H48SA manual Typical input characteristics at room temperature

Models: Series H48SA

1 14
Download 14 pages 23.69 Kb
Page 4
Image 4

ELECTRICAL CHARACTERISTICS CURVES

 

95

 

 

 

 

 

90

 

 

 

 

 

 

 

 

75Vin

 

(%)

85

 

48Vin

 

 

 

 

 

 

 

EFFICIENCY

80

 

36Vin

 

 

75

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

65

 

 

 

 

 

60

 

 

 

 

 

5

10

15

20

25

OUTPUT CURRENT (A)

 

30

 

 

 

 

 

 

25

 

 

 

 

 

(W)

 

 

75Vin

 

 

 

 

 

 

 

 

 

DISSIPATION

20

48Vin

 

 

 

 

15

36Vin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

10

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

0

 

 

 

 

 

 

0

5

10

15

20

25

OUTPUT CURRENT (A)

Figure 5: Efficiency vs. output voltage for minimum, nominal, and maximum input voltage at 25°C, Vout=13.2V.

Figure 6: Power dissipation vs. output voltage for minimum, nominal, and maximum input voltage at 25°C, Vout=13.2V.

 

12

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

(V)

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

8

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

0

Output

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

30.0

31.3

33.6

35.0

40.0

45.0

50.0

55.0

60.0

65.0

70.0

75.0

Output Current (A)

Figure 7: Typical input characteristics at room temperature.

Figure 8: Turn-on transient at full rated load current, 4ms/div:

Top Trace: Vout, 5V/div; Bottom Trace: ON/OFF input, 5V/div.

4

DS_H48SA12025_05052008