3 - 8 Operation
chamber is pressurized, the Purge Pressure Indica-
tor will read system pressure.)
12. The Normal Start-Up or Restart procedure for mod-
els LS60 through LS1000 is now complete. Proceed
to the Normal Operational Checks section of this
manual for final operational checks and adjustments.
Dryer Models LS1250 and LS1500
1. Close the Pilot Gas Filter's Bleed Valve.
2. Close any manual vent or drain valves installed in
prefilter and afterfilter assemblies.
3. Close the System Outlet Isolation Valve (customer
supplied).
4. Open the Pilot Gas Supply Valve, located upstream
of the Pilot Gas Filter.
5. Supply pressure to system by slowly opening the
System Inlet Isolation Valve (customer supplied).
The Right Chamber Inlet Switching Valve and Left
Chamber Purge Exhaust Switching Valve will close.
The Left Chamber will immediately begin pressurizing
to system pressure as indicated by the chamber
pressure gauge.
6. Fully open the Moisture Indicator Supply Valve.
7. The Moisture Indicator's (if dryer so-equipped) bleed
valve is installed directly into the back of the
indicator's body. Adjust the Moisture Indicators
Bleed Valve until a very slight, continuous gas bleed
is felt exhausting from the bleed valves exhaust port.
Ensure that the granular indicator crystals remain
motionless after final adjustment.
8. PARTIALLY open the System Outlet Isolation Valve
(customer supplied), while monitoring the outlet pres-
sure gauge. Do not permit the Dryer's Outlet Pres-
sure gauge to exceed a 5% drop in pressure while
pressurizing downstream piping.
9. Close the System Bypass Valve (if gas system has
been so-equipped).
10. Energize the dryer's electrical power supply.
11. Refer to Appendix A (Appendix C for -100°F pdp) of
this manual and calculate your dryer model's purge
pressure setting as instructed.
12. Locate the Purge Adjusting Valve. Slowly rotate
dryers Purge Adjusting Valve until the Purge Pres-
sure Indicator indicates the calculated purge pressure
setting. (See following Note).
Note: The purge pressure can only be read and ad-
justed when an off-line desiccant chamber has de-
pressurized for regeneration. (When the off-line cham-
ber is pressurized, the Purge Pressure Indicator will
read system pressure.)
13. The Normal Start-Up or Restart procedure for mod-
els LS1250 through LS1500 is now complete. Pro-
ceed to the Normal Operational Checks section of
this manual for final operational checks and adjust-
ments.
Dryer Models LS2070 and LS2580
1. Close the Pilot Gas Filter's Bleed Valve.
2. Close any manual vent or drain valves installed in
prefilter and afterfilter assemblies.
3. Close the System Outlet Isolation Valve (customer
supplied).
4. Close the Pilot Gas Supply Valve and pressurize the
pilot gas system with compressed gas to line pres-
sure. Use the Ball Valve located in the pilot gas line
prior to the Pilot Gas Filter and after the Pilot Gas
Supply Valve. Both desiccant chamber Inlet Valves
will open and both Purge Exhaust Valves will close.
5. Supply pressure to system by slowly opening the
System Inlet Isolation Valve (customer supplied).
Both Inlet Switching Valves are open. Both Purge
Exhaust Switching Valves are closed (see step 4).
The desiccant chambers will immediately begin pres-
surizing to system pressure as indicated by chamber
pressure gauges.
6. Fully open the Moisture Indicator Supply Valve.
7. The Moisture Indicator's (if dryer so-equipped) bleed
valve is installed directly into the back of the
indicator's body. Adjust the Moisture Indicators
Bleed Valve until a very slight, continuous gas bleed
is felt exhausting from the bleed valves exhaust port.
Ensure that the granular indicator crystals remain
motionless after final adjustment.
8. PARTIALLY open the System Outlet Isolation Valve
(customer supplied), while monitoring the outlet pres-
sure gauge. Do not permit the Dryer's Outlet Pres-
sure gauge to exceed a 5% drop in pressure while
pressurizing downstream piping.
9. Close the System Bypass Valve (if gas system has
been so-equipped).
10. Energize the dryer's electrical power supply.
11. Refer to Appendix A (Appendix C for -100°F pdp) of
this manual and calculate your dryer model's purge
pressure setting as instructed.
12. Locate the Purge Adjusting Valve. Slowly rotate
dryers Purge Adjusting Valve until the Purge Pres-
sure Indicator indicates the calculated purge pres-
sure setting. (See following Note).
Note: The purge pressure can only be read and ad-
justed when an off-line desiccant chamber has de-