Operation 3 - 7
20. The Start-Up procedure for models LS2070 and
LS2580 is now complete. Proceed to the Normal
Operation Checks section of this manual for final op-
erational checks and adjustments.
3.5 Normal Start-Up or RestartFor Dryers With Fixed CycleElectronic Timer Control
(Models LS60 through LS1000 only)
1. Close the Pilot Gas Filter's Bleed Valve.
2. Close any manual vent or drain valves installed in
prefilter and afterfilter assemblies.
3. Close the System Outlet Isolation Valve (customer
supplied).
4. Energize the dryers electrical power supply.
The following indicator lights will illuminate:
a) POWER ON
b) LEFT or RIGHT CHAMBER DRYING
Note: Should the dryer experience a power inter-
ruption during a normal cycle, the unit will return to
the same status of operation that existed at the time
of the power interruption.
5. Supply pressure to system by slowly opening the
System Inlet Isolation Valve (customer supplied).
The Right Chamber Inlet Switching Valve and Left
Chamber Purge Exhaust Switching Valve will close.
The Left Chamber will immediately begin pressurizing
to system pressure as indicated by the chamber
pressure gauge.
6. PARTIALLY open the System Outlet Isolation Valve
(customer supplied), while monitoring the outlet pres-
sure gauge. Do not permit the Dryer's Outlet Pres-
sure gauge to exceed a 5% drop in pressure while
pressurizing downstream piping.
7. Close the System Bypass Valve (if gas system has
been so-equipped).
8. Refer to Appendix A (Appendix C for -100°F pdp) of
this manual and calculate your dryer model's purge
pressure setting as instructed.
9. Locate the Purge Adjusting Valve. Slowly rotate
dryers Purge Adjusting Valve until the Purge Pres-
sure Indicator indicates the calculated purge pressure
setting. (See following Note).
Note: The purge pressure can only be read and ad-
justed when an off-line desiccant chamber has de-
pressurized for regeneration. (When the off-line
chamber is pressurized, the Purge Pressure Indica-
tor will read system pressure.)
10. The Normal Start-Up or Restart procedure for mod-
els LS60 through LS1000 is now complete. Proceed
to the Normal Operational Checks section of this
manual for final operational checks and adjust-
ments.
3.6 Normal Start-Up or RestartFor Dryers With DECController

Dryer Models LS60 through LS1000

1. Close the Pilot Gas Filter's Bleed Valve.
2. Close any manual vent or drain valves installed in
prefilter and afterfilter assemblies.
3. Close the System Outlet Isolation Valve (customer
supplied).
4. Energize the dryer's electrical power supply.
5. Supply pressure to system by slowly opening the
System Inlet Isolation Valve (customer supplied).
Both desiccant chamber Inlet Switching Valves will
open and both Purge Exhaust Switching Valves will
close. The desiccant chambers will immediately be-
gin pressurizing to system pressure as indicated by
chamber pressure.
6. Fully open the Moisture Indicator Supply Valve.
7. The Moisture Indicator's (if dryer so-equipped) bleed
valve is installed directly into the back of the
indicator's body. Adjust the Moisture Indicators
Bleed Valve until a very slight, continuous gas bleed
is felt exhausting from the bleed valves exhaust port.
Ensure that the granular indicator crystals remain
motionless after final adjustment.
8. PARTIALLY open the System Outlet Isolation Valve
(customer supplied), while monitoring the outlet pres-
sure gauge. Do not permit the Dryer's Outlet Pres-
sure gauge to exceed a 5% drop in pressure while
pressurizing downstream piping.
9. Close the System Bypass Valve (if gas system has
been so-equipped).
10. Refer to Appendix A (Appendix C for -100°F pdp) of
this manual and calculate your dryer model's purge
pressure setting as instructed.
11. Locate the Purge Adjusting Valve. Slowly rotate
dryers Purge Adjusting Valve until the Purge Pres-
sure Indicator indicates the calculated purge pressure
setting. (See following Note).
Note: The purge pressure can only be read and ad-
justed when an off-line desiccant chamber has de-
pressurized for regeneration. (When the off-line