186
D.2 Interface Cables
With the interface cables described in this section, DENSO WAVE has run the quality
assurance test conforming to the EMC Directive for the BHT-100Q/100B series and CU-
7001.
Any connectors other than those specified here are not acceptable. They may cause
the BHT or CU to fail to work according to the specifications.
For BHT
Cable 1
Wind the cable on a ferrite core twice and then secure the core with a heat-shrinkable
tube.
Connector P161 Teisin Electric Co., Ltd.
D-sub connector D -F-T-N series (EMI-durable) Japan Aviation
Electronics Industry Ltd.
Connector cover 17JE series hood/cable clamp DDK Ltd.
(shielded)
Cable Super flex VVC 7/0.18 mm x 3C Bando Densen Co., Ltd.
Ferrite core ZCAT2035-0930A TDK Corporation
Heat-shrinkable tube
Note: A square ( ) in the above specifications denotes a numeral that will vary
according to the number of connector pins.